Manometer

 

SR8920, SR8921, SR8922, SR8923, SR8925 Manometer

This product is aimed to measure positive and negative differential pressure value. Here are some units of measurements for choice InH2O, psi, bar, mbar, kPa, inHg, mmHg, Ozin2, ftH2O, cmH2O, kgcm2. The product is equipped with simple hose connection. It is suitable for the measurement of ventilation and air conditioning systems and field check Clean rooms, or any troubleshooting gas pressure system. Easy operation and clear reading.

Features:

* 11 Selectable units of Measure

* Max/ minimum/ average, and with a relative time

* Large LCD backlit dual display

* Zeroing, offset, and data compensation

* Low battery display and automatic shutdown

* Data Hold and Error code

Specifications:

 

Unit

SR8920

SR8921

SR8922

SR8923

SR8925

Range

Resolution

Range

Resolution

Range

Resolution

Range

Resolution

Range

Resolution

Range

InH2O

±55.40

0.01

±138

0.1

±415.2

0.1

±830

1

±2078

1

Psi

±2.000

0.001

±5.000

0.001

±15.00

0.01

±30.00

0.01

±75.00

0.01

Mbar

±137.8

0.1

±344.7

0.1

±1034

4

±2068

1

±5168

1

Kpa

±13.79

0.01

±34.47

0.01

±103.4

0.1

±206.8

0.1

±517.1

0.1

InHg

±0.407

0.001

±1.018

0.001

±30.54

0.01

±61.08

0.01

±15.00

0.01

MmHg

±103.4

0.1

±258.5

0.1

±775.7

0.1

±1551

1

±3878

1

Ozin2

±32.00

0.01

±80

1

±240.0

0.1

±480.0

0.1

±1200

1

FtH2O

±4.612

0.001

±11.53

0.01

±34.60

0.01

±69.20

0.01

±173.0

0.1

CmH2O

±140.6

0.1

±351.5

0.1

±1055

1

±2109

1

±5272

1

Kgcm2

±0.140

0.001

±0.351

0.001

±1.055

0.001

±2.109

0.001

±5.250

0.001

Bar

±0.137

0.001

±0.344

0.001

±1.034

0.001

±2.068

0.001

±5.138

0.001

Maximum Pressure

Psi

10

10

100

100

100

Accuracy

±0.3%FSO (25°C)

Repeatability

±0.2% (Max0.5%FSO)

Linearity/ Hysteresis

0.29%FSO

Pressure connector

1/8”(3.18mm) quick connector

Operating Temperature

0-40°C

Storage Temperature

-10-60°C

Overrange Indication

ERR1 or ERR2

Work current

6F22 9.0V

 

 

Applications:
1.HVAC/R refrigeration air-conditioning industry
2.Medical facilities
3.Measure negative and positive pressure
6.Computer peripheral equipment pneumatic control
7.Experimental and teaching use, understand the different environment of air pressure and differential pressure.
8.Differential pressure power generation, in order to effectively use all kinds of natural energy or wasted energy.

Manometer SR8100

Specifications:

1.Pressure Range:+2psi
2.Accuracy:+0.3% FSO (at 25º C)
3.Repeatability: +0.2% (Max+0.5%FSO )
4.Linearity/Hysteresis:+0.29% FSO
5.Response Time:0.5Seconds Typical
6.Over Range Indicator: Hi
7.Under Range Indicator: Lo
8.Operating Conditions:0 to 50
º C(32 to 122º F)
9.Storage Conditions:-10 to 60
º C (14 to 140º F)
10.11 Selectable units of Measure
11.Max / minimum / average, and with a relative time
12.Large LCD backlit dual display
13.Zeroing, offset, and data compensation
14.Low battery display and automatic shutdown
15.Data Hold and Error code
16.9Vbattery
17.Client can calibrate the meter by oneself

 

Range

Resolution

InH2O

+/-55.35

0.01

Ozin2

+/-32

0.01

Psi

+/-2

0.001

FtH2O

+/-4.613

0.001

Mbar

+/-137.8

0.1

cmH2O

+/-140.6

0.1

kPa

+/-13.78

0.01

Kgfcm2

+/-0.14

0.001

inHg

+/-4.07

0.001

Bar

+/-0.137

0.001

mmHg

+/-103.4

0.1

Packing: Blister

   

Applications:
1.HVAC/R refrigeration air-conditioning industry
2.Medical facilities
3.Measure negative and positive pressure
6.Computer peripheral equipment pneumatic control
7.Experimental and teaching use, understand the different environment of air pressure and differential pressure.
8.Differential pressure power generation, in order to effectively use all kinds of natural energy or wasted energy.

Manometer SR8101

Specifications:

1.Pressure Range:+5psi
2.Accuracy:+0.3% FSO (at 25
º C)
3.Repeatability: +0.2% (Max+0.5%FSO)
4.Linearity/Hysteresis:+0.29% FSO
5.Response Time:0.5Seconds Typical
6.Over Range Indicator: Hi
7.Under Range Indicator: Lo
8.Operating Conditions:0 to 50
º C(32 to 122º F)
9.Storage Conditions:-10 to 60
º C (14 to 140º F)
10.11 Selectable units of Measure
11.Max / minimum / average, and with a relative time
12.Large LCD backlit dual display
13.Zeroing, offset, and data compensation
14.Low battery display and automatic shutdown
15.Data Hold and Error code
16.9Vbattery
17.Client can calibrate the meter by oneself

 

Range

Resolution

InH2O

+/-138.3

0.01

Ozin2

+/-80

0.01

Psi

+/-5

0.001

FtH2O

+/-11.53

0.001

Mbar

+/-344.7

0.1

cmH2O

+/-351.5

0.1

kPa

+/-34.47

0.01

Kgfcm2

+/-0.351

0.001

inHg

+/-10.18

0.001

Bar

+/-0.344

0.001

mmHg

+/-258.5

0.1

Packing: Blister

 

   

Applications:
1.HVAC/R refrigeration air-conditioning industry
2.Medical facilities
3.Measure negative and positive pressure
6.Computer peripheral equipment pneumatic control
7.Experimental and teaching use, understand the different environment of air pressure and differential pressure.
8.Differential pressure power generation, in order to effectively use all kinds of natural energy or wasted energy.

Manometer SR8102

Specifications:

1.Pressure Range:+10psi
2.Accuracy:+0.3% FSO (at 25
º C)
3.Repeatability: +0.2% (Max+0.5%FSO)
4.Linearity/Hysteresis:+0.29% FSO
5.Response Time:0.5Seconds Typical
6.Over Range Indicator: Hi
7.Under Range Indicator: Lo
8.Operating Conditions:0 to 50
º C(32 to 122º F)
9.Storage Conditions:-10 to 60
º C (14 to 140º F)
10.11 Selectable units of Measure
11.Max / minimum / average, and with a relative time
12.Large LCD backlit dual display
13.Zeroing, offset, and data compensation
14.Low battery display and automatic shutdown
15.Data Hold and Error code
16.9Vbattery
17.Client can calibrate the meter by oneself

 

Range

Resolution

InH2O

+/-276.7

0.01

Ozin2

+/-160

0.01

Psi

+/-10

0.001

FtH2O

+/-23.06

0.001

Mbar

+/-689.4

0.1

cmH2O

+/-703

0.1

kPa

+/-68.94

0.01

Kgfcm2

+/-0.703

0.001

inHg

+/-20.36

0.001

Bar

+/-0.689

0.001

mmHg

+/-517.1

0.1

Packing: Blister

   

SR8070 Absolute pressure meter

Features:

SR8070 is an absolute pressure measuring instrument with 8 units (Pa, hPa, mbar, mmH2O, mmHg, inHG, inH2O, psi).
It is normally used to measure absolute pressure, e.g. for pressure compensation in velocity measurement in ducts, laboratories and production processes.
Barometric measurements and height measurements between two points are also possible. With hold, MAX, MIN and AVG function, SR8080 is widely used in HVAC, laboratories and architecture project.
With our reputation for quality products, you can find it is the most economic instruments for pressure meter.
Specifications:

• Display: 6 digits LCD Display
• Parameters (absolute/barometric): Pa, hPa, mbar, mmH2O, mmHg,inHG, inH2O, psi
• Resolution: 0.1 hPa, 0.1 inH2O
• Range: 300…1,200 hPa, 120.4…481.8inH2O
• Accuracy: ±3.0hPa, ±1.2 inH2O
• Basic conditions 18.0 º C~28.0 º C, Humidity<80%
• Sample rate: 1 time /sec
• Auto power off: about 20 minutes
• Low battery indicator
• Operating environment: 0 º C ~ 50  º C(32º F~122º F), 0 ~ 80%RH
• Storage environment: -20 º C ~ 60 º C(-4º F~140º F), 0 ~ 80%RH

Accessories included:
Free 1.5V( AAA battery) x 3
Free Sturdy Carrying Case with hardened & contoured foam inside
Free Wrist Strap
User's Manual

   

Manometer SR8290

Features:
1. Large LCD backlit dual display
2. Data Retention
3. Max / minimum / average, and with a relative time
4. Zeroing, offset, and data compensation
5. Low battery display and automatic shutdown
6. Data record
7. Error code

Specifications:
Accuracy:+/-0.3% FSO (25 º C)

Repeatability:+/-0.2% (Max+/-0.5%FSO)

Maximum Pressure:10psi
Response Time:0.5Seconds Typical
Low Range Indicator:Err.1
Under Range Indicator:Err.2
Operating Conditions:32 º F to 122 º F(0 to 50 º C)

 

Range

Resolution

InH2O

+/-55.40

0.01

Ozin2

+/-32.00

0.01

Psi

+/-2.000

0.001

FtH2O

+/-4.612

0.001

Mbar

+/-137.8

0.1

cmH2O

+/-140.6

0.1

kPa

+/-13.79

0.01

Kgcm2

+/-0.140

0.001

inHg

+/-0.407

0.001

Bar

+/-0.137

0.001

mmHg

+/-103.4

0.1

Packing: Blister

   

Manometer SR8291

Specifications:

Display: Dual LCD
Accuracy:0.3% FSO (25 º C)
Repeatability:0.2% (Max0.5%FSO)
Linearity/Hysteresis:0.29% FSO
Maximum Pressure:20psi(HT-1891)
Response Time:0.5Seconds Typical
Low Range Indicator:Err.1
Under Range Indicator:Err.2
Operating Conditions:32 º F to 122 º F(0 to 50 º C)

 

Range

Resolution

InH2O

+ 138.3

0.01

Psi

+5.000

0.001

Mbar

+344.7

0.1

kPa

+34.47

0.01

inHg

+1.018

0.001

mmHg

+258.5

0.1

Ozin2

80

0.01

FtH2O

11.53

0.001

cmH2O

351.5

0.1

Kgcm2

0.351

0.001

Bar

0.344

0.001

Packing: Blister
   

Manometer SR8295

Specifications:

Display: Dual LCD
Accuracy:0.3% FSO (25 º C)
Repeatability:0.2% (Max0.5%FSO)
Linearity/Hysteresis: 0.29% FSO
Maximum Pressure:150psi
Response Time:0.5Seconds Typical
Low Range Indicator:Err.1
Under Range Indicator:Err.2
Operating Conditions:32 º F to 122 º F(0 to 50 º C)

 

Range

Resolution

InH2O

+2078

1

Psi

+75.00

0.01

Mbar

+5168

1

kPa

+517.1

0.1

inHg

+15.00

0.01

mmHg

+3878

1

Ozin2

1200

1

FtH2O

173.0

0.1

cmH2O

5272

1

Kgcm2

5.250

0.001

Bar

5.138

0.001

Packing: Blister

   

SR8210 Pressure Manometer

1. Measuring range:+/-10kPa
2. Display: LCD Display
3. Accuracy:+/-0.3%FSO(25º C)
4. Repeatability:+/-0.2%(Maximum+/-0.5%FSO)
5. Linearity / Hysteresis:+/-0.29%FSO
6. Maximum pressure:50kPa

7. Response time: Typical 0.5 s
8. Low battery indicator function
9. Up overload alert:Err.1
10. Up overload alert:Err.2
11. Operating temperature:0-50º C
12. Storage Temperature:-10-60º C
13. Power:4AAA* battery
14. USB Interface

15  Without Temperature compensation function

   

SR8211 Pressure Manometer

1. Measuring range:+/-10kPa
2. Display: LCD Display
3. Accuracy:+/-0.3%FSO(25º C)
4. Repeatability:+/-0.2%(Maximum+/-0.5%FSO)
5. Linearity / Hysteresis:+/-0.29%FSO
6. Maximum pressure:50kPa

7. Response time: Typical 0.5 s
8. Low battery indicator function
9. Up overload alert:Err.1
10. Up overload alert:Err.2
11. Operating temperature:0-50º C
12. Storage Temperature:-10-60º C
13. Power:4AAA* battery
14. USB Interface

15  With Temperature compensation function

   

SR8212 Pressure Manometer

1. Measuring range:+/-35kPa
2. Display: LCD Display
3. Accuracy:+/-0.3%FSO(25º C)
4. Repeatability:+/-0.2%(Maximum+/-0.5%FSO)
5. Linearity / Hysteresis:+/-0.29%FSO
6. Maximum pressure:150kPa

7. Response time: Typical 0.5 s
8. Low battery indicator function
9. Up overload alert:Err.1
10. Up overload alert:Err.2
11. Operating temperature:0-50º C
12. Storage Temperature:-10-60º C
13. Power:4AAA* battery
14. USB Interface

15  With Temperature compensation function

 

 

 ( If you need user manual or E-catalogue for above meters, please ask for at: xiushunjie@163.com )