TDS Meter, Conductivity Meter / Conductometer, EC Meter, CF Meter

¡¡

TDS meter          EC/CF (conductivity), salinity meter          bench-top TDS/conductivity meter         Soil EC Tester
¡¡

bench-top conductivity meter

¡¡

DDS-W SERIES MICROPROCESSOR CONDUCTIVITY METER

Single Point Push-Button Calibration:
DDS-W series with single point calibration function, you need only set conductivity value of the calibration solution at 25oC and immerse conductivity electrode into solution, then press [ENTER] key, the meter will calibrated automatically.
Auto-Ranging for Conductivity:
The meter with auto-ranging function when measure conductivity. After electrode immersed in solution, the meter will fast response and convert range.
Auto Temperature Compensation:
DDS-12DW will recognize the temperature sensor automatically and measure temperature after temperature sensor connected to the meter. If the conductivity electrode connected to it, the meter will

enter automatic temperature compensation.

Adjustable Temperature Coefficient:
Different ion solution usually have different temperature coefficient, setting temperature coefficient correctly is very important to measurement, DDS-W series can be set in the range of 0 to 3.9%per centigrade degree.

Adjustable Cell Constant:

When measuring higher or lower conductivity solution, you should choose conductivity electrode with

different constant. The meter with three cell constant (0.1,1,10) for your choice.¡¡

What's included:

DJS-1 conductivity electrode(K=1), electrode holder, 9V power adapters, temperature probe (only for

DDS-12DW)

Model ¡¡ DDS-11AW DDS-307W ¡¡ DDS-12DW

   Conductivity Range

¡¡

0~1.999, 19.99, 199.9,

1999uS/cm, 19.99, 199.9mS/cm

   Conductivity Accuracy ¡¡ ¡À1.5% F.S ¡À1% F.S ¡À1% F.S
   Temperature Range ¡¡ --- --- 0~100oC
   Temperature Accuracy ¡¡ --- --- ¡À1oC
   Calibration Points ¡¡ 1 Point
   Calibration Solution ¡¡ 146.6uS/cm, 1408uS/cm, 12.85mS/cm
   Temperature Compensation ¡¡ 0~50oC, Manual 0~50oC, Manual 0~50oC, Manual or Automatic
   Temperature Coefficient ¡¡ 0~3.9%/oC
   Cell Constant ¡¡ K=0.1, 1, 10, Adjustable
   Display ¡¡ LCD
   Power Requirements ¡¡ 9VDC, using AC adapters 220VAC, 50Hz
   Dimensions ¡¡ 210(L)mm¡Á205(W)mm¡Á65(H)mm
    Weight ¡¡ 1.5kg
¡¡ ¡¡

   

PHS510 Benchtop Conductivity/TDS/¡ãC/¡ãF Meter

Order code and Accessories:

PHS510-S: DJS-1 Conductivity Electrode, Temperature probe, Power Adapters
PHS510-DH: DJS-10 Conductivity Electrode, Temperature probe, Power Adapters
PHS510-DL: DJS-0.1 Conductivity Electrode, Temperature probe, Power Adapters

Specification:

Model

PHS510

Conductivity Range

0~20mS/cm (Max.200mS/cm)

Conductivity Accuracy

¡À1% Full Scale

Calibration Points

Up to 3 points

Calibration Solutions

10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm

TDS Range

0~10ppt (Max. 20ppt)

TDS Accuracy

¡À1% Full Scale

TDS Factor

0.1~1.0 (Default 0.5)

Temperature Range

0~105¡ãC, 32~221¡ãF

Temperature Accuracy  

¡À1¡ãC

Temperature Calibration

Manual

Temperature Compensation

0~100¡ãC, 32~212¡ãF, Automatic or Manual

Temperature Coefficient

0.0~10.0% per ¡ãC

Cell Constant

K=0.1, 1, 10, Selectable

Normalization Temperature

25¡ãC

Auto-Off

Manual or Automatic (180 minutes after last key pressed)

Hold Function

Manual or Automatic endpoint

Reset Function

Yes

Connector

6-pin

LCD Display

Custom Dual-Display LCD (135¡Á75mm)

Power Requirements

DC9V, using AC adapters, 220VAC/50Hz

Dimensions

210(L)¡Á205(W)¡Á75(H)mm

Weight

1.2kg

¡¡ ¡¡

Features:
Up to 5-point push-button calibration allows user to uses customized calibration solutions.
Adjustable TDS factors, cell constants, temperature coefficients and normalization temperature.
In salinity measurement modes, selectable practical salinity (PSU) or seawater measurement standard (ppt).
Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.
Manual temperature calibration provides accurate temperature value.
Selectable either temperature units between degrees Celsius (¡ãC) and degrees Fahrenheit (¡ãF).
Selectable linear or pure water compensation modes.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for easy reading and recording data.
Help message as a operational guide to helps you understand how to use meter.
Setup menu lets user customize calibration points, stability conditions, temperature units, date and time to meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication interface.

PHS950 Precision Conductivity/TDS/Salinity/Resistivity/¡ãC/¡ãF Meter

PHS950 meter is used for measuring conductivity, Total Dissolved Solid (TDS), salinity, resistivity and temperature in liquids.

SPECIFICATIONS:

¡¡

Model PHS950
   Conductivity Range 0~20mS/cm (Max.200mS/cm)
   Conductivity Accuracy ¡À0.5% Full Scale
   Calibration Points Up to 5 points
   Calibration Solutions 10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
   TDS Range 0~10ppt (Max. 20ppt)
   TDS Accuracy ¡À1% Full Scale
   TDS Factor 0.1~1.0 (Default 0.5)
   Salinity Range 0~10ppt (Max. 80ppt)
   Salinity Accuracy ¡À1% Full Scale
   Salinity Measurement Modes Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
   Resistivtiy Range 0~100M¦¸
   Resistivtiy Accuracy ¡À1% Full Scale
   Resolution 0.001, 0.01, 0.1, 1, Automatic
   Temperature Range 0~105¡ãC, 32~221¡ãF
   Temperature Accuracy ¡À0.5¡ãC, ¡À0.9¡ãF
   Temperature Calibration Manual
   Temperature Compensation 0~100¡ãC, 32~212¡ãF, Automatic or Manual
   Temperature Coefficient 0.0~10.0% per ¡ãC
   Compensation Modes Linear or Pure Water
   Cell Constant

K=0.1, 1, 10, Selectable

   Normalization Temperature

20¡ãC or 25¡ãC

   Auto-Off

Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable)

   Hold Function

Manual or Automatic endpoint

   Stability Conditions

Low or High, Selectable

   Calibration due reminder

1 to 30 days or Off

   Reset Function

Yes

   Sensor Type

Platinum (Order Code: DJS-0.1, DJS-1 or DJS-10)

   Connector

6-pin

   Memory

500 data sets with Date/Time stamping

   Output

USB Communication Interface

   LCD Display

Custom dual-display LCD (130¡Á110mm)

   Power Requirements

DC5V, using AC adapters, 220VAC/50Hz

   Dimensions

210(L)¡Á188(W)¡Á60(H)mm

   Weight

1.2kg

Order code and Accessories:

PHS950-S: DJS-1 Conductivity Electrode, Temperature probe, Power Adapters
PHS950-DH: DJS-10 Conductivity Electrode, Temperature probe, Power Adapters
PHS950-DL: DJS-0.1 Conductivity Electrode, Temperature probe, Power Adapters

¡¡ ¡¡

DDS-307 Conductivity Meter

Model

DDS-307

Range

0.001~2¦ÌS/cm

0.01~20¦ÌS/cm

0.1~200¦ÌS/cm

0.001~2ms/cm

0.01~20ms/cm

0.1~200mS/cm

Accuracy

¡À1% Full Scale

Power

DC9V 100mA

Operating Conditions

Temperature: 5~40ºC

Humidity: 90% maximum

Dimensions

208¡Á200¡Á76mm

Weight

390g

¡¡

¡¡ ¡¡

Optional accessories:

1. DJS-1 bright electrode

2. DJS-10 Conductivity electrode

3. DJS-0.1 Platinum electrode

4. DJS-0.01 Titanium alloy electrode

Overall dimension & weight:

Shipping package dimension: 332-265-275mm

Gross weight: 3kg Net weight: 2kg

SRS-307 Conductivity Meter
Characteristics:

1. 31/2LED display
2. With manual temperature compensation.
3. There are four types of electrodes for conduction cell constant: 0.01,0.1,1.0 and 10.0cm-1 ,user can select by your need.
4. Automatic switching measuring frequency, measuring ultrapure water with using K=0.01cm-1 titanium alloy electrode and sealing measuring cell
5. With 0~10mV output signal
Specifications:
1. Measurement range: 0-1¡Á105 mS/cm
There is the best correspondence point between conductivity measuring range and conduction cell constant

conduction cell constant(cm-1 )

0.01

0.1

1

10

Measuring range (uS/cm)

0~2

0.2~20

2~1¡Á104

1¡Á104~1¡Á105

2. Electrode constant, cm-1: 0.01. 0.1, 1.0.10.0
3. Accuracy of the electric unit: ¡À0.5%(FS) ¡À1 bit
4. Stability of the electronic unit: ¡À0.33%(FS) ¡À1bit/3h
5. Accuracy ¡À1.0%(FS) ¡À1 bit
6. The range of temperature compensation: 15-35ºC, basic temperature: 25ºC

Standard configuration:

1. Main instrument 1
2. Power cable 1
3. Platinum-black Electrode DJS-1C 1
4. Multi-function Electrode support stand 1
¡¡ ¡¡

SRS-307A Conductivity/TDS/ºC Meter

Functions:

Large screen and LCD segmented display

It functions as automatic and manual temperature compensation.

If matched with the titanium alloy sensor of 0.01cm-1  and sealed measuring reservoir, it can test high purity water.

It is equipped with DJS-1C conductancesensor(platinum black) and T-818-B-6 temperaturesensor.

   Specifications:

1, Measuring range:

Conductivity: 0.00μS/cm~100μS/cm

         TDS: 0~1000 mg/L

Temperature: 0.0~60.0 ºC
      2, Accuracy:

         Conductivity: ±0.5%FS

         T D S: ±1.0%FS)        

Temperature: ±0.3ºC±1 bit
      3
,
Stability: (±0.33%FS±1 digital) /3h
      4
, Temperature compensation range: Manual/Automatic (0.0~40.0)
ºC

      5, Temperature compensation coefficient: 2%

      6, Power supply:: AC(220±22)V; (50±l)Hz

      7, Dimension(mm): 300×200×72

      8, Weight: 1.5kg

9, Case outside serial No: WXS-A008-1

Conductance Constant and corresponding Conductivity measuring range

Electrodeconstant (K) (cm-1) 0.01 0.1 1 10
Measuring range(¦ÌS/cm) 0.0~2.0 0.2~20.0 2~1¡Á104 1¡Á104~1¡Á105
¡¡ ¡¡

¡¡

¡¡

Standard Configuration:

No.

Descriptions and Specifications

Quantity

1

SRS-308F Conductivity Meter

1 set

2

Conductive probe(Platinum black, K=1)

1

3

ATC Probe

1

4

Universal power supply (9V DC, 500mA,)

1

5

Electrode Holder

1

6

Communication Line

1

7

TP-16 Printer Line

1

8

Protective Caver

1

9

Operation Manual

1

¡¡

SRS-308F Benchtop Conductivity Meter

Conductivity/Resistivity/TDS/Salinity/Temp

Characteristics:

1. Smart-Read function: More stable the reading with auto recognition end-point

Timed-Read function: Auto timed to store the reading

Cont-Read function: It is clear to read continuously the sample changing in measurement process

2. More accuracy measurement with reminder the electrode performance and calibration

3. Auto upgrade hardware: Complete and simple user¡¯s operation

4. Support GLP norm: More complete checking the stored information

The meter requires setting operator No and records the all operating procedures.

It can record, view and print calibration data.

It can store measuring data(600 sets) which follows GLP norm.

Support view, print, delete stored data

5. Large and light screen: displaying measurement value, temperature value, constant, measurement mode, operation date and time

6. Auto temperature compensation, range switch and frequency switch

7. Support calibration(constant or TDS factor, up to two point calibration)

8. No calculation: displaying conductivity, resistivity, TDS, salinity.

9. Support USB

10. Supports the function of power-off protection, protect your data

Specifications:

        Model

SRS-308F

Specifications

Parameters

Conductivity/Resistivity/TDS/Salinity/¡æ

Range

Conductivity

0.000¦ÌS/cm - 199.9mS/cm

Resistivity

5.00¦¸¡¤cm - 20.00M¦¸¡¤cm

TDS

0.000 mg/L - 99.9g/L

Salinity

(0.00 - 8.00)%

Temperature

-5.0 - 110.0¡æ

Accuracy

Conductivity

¡À0.5%FS

TDS

¡À0.5%FS

Salinity

¡À0.1%

Temperature

¡À0.2¡æ

Stability

¡À0.3%(FS)/3h

Temp compensation

Manual/Auto(-5.0 - 110.0)¡æ

Temp coefficient

Adjustable

Display

LCD screen, backlight

Power

Universal power adapter

 (9V DC,800mA, inside ¨C positive, outside ¨C negative)

Dimension (mm), Weight(kg)

280¡Á215¡Á92, 1

¡¡ ¡¡

Standard Configuration

Order No

Product Name and Specification

Quantity

1.

SRSJ-318 conductivity meter

1

2.

Platinum black electrode(K=1)

1

3.

Temperature sensor

1

4.

Multifunctional electrode holder

1

5.

Power source(9VDC,800mA,inside-positive and outside-negative)

1

¡¡

Optional Accessories

Order No

Product Name and Specification

Quantity

1.

Bright electrode(K=1)

1

2.

Conductivity electrode(K=10)

1

3.

Platinum electrode(K=0.1)

1

4.

Titanium alloy electrode(K=0.01)

1

¡¡

Functions:
1. It can measure conductivity, resistivity. TDS£¨total dissolved solids£©, salinity and temperature of the current solution.
2. It applies microprocessor-based technology and functions as automatic temperature compensation, auto-calibration, auto measuring range switch.
3. The user can calibrate the electrode constant or TDS conversion coefficient. Also, the instrument supports two-point calibration.
4. 5.7 inch large touch screen, friendly English language interface for easy use
5. It follows GLP practice
6. The stored data can be displayed by graphics and can be viewed, printed and deleted.
7. It allows the user to review current measuring date and the last calibration data.
8. It contains 3 kinds of measuring modes: Continuous measurement, timed measurement and balance measurement which can meet different measuring requirements.
9. It has RS-232 interface and USB. If matched with data collecting software, it can be communicated with PC.

SRS-318 Conductivity Meter (touch screen)

¡¡

SPECIFICATION:

        Model

Specifications

SRSJ-318

Parameters

Conductivity/Resistivity/TDS/Salinity/¡ãC

Range

 

Conductivity

0.055¦ÌS/cm~199.9mS/cm

( full range measuring, no need to exchange electrode)

Resistivity

5.00¦¸¡¤cm~18.25M¦¸¡¤cm

TDS

0.000 mg/L~100g/L

Salinity

(0.00~8.00)%

Temperature

-5.0~135.0¡ãC

Resolution

Conductivity

0.001¦ÌS/cm

Resistivity

0.01¦¸¡¤cm

TDS

0.001 mg/L

Salinity

0.01%

Temperature

0.1¡ãC

Accuracy

Conductivity

¡À0.5%FS

Resistivity

¡À0.5%FS

TDS

¡À0.5%FS

Salinity

¡À0.1%

Temperature

¡À0.3¡ãC

Temp compensation

Manual/Auto (-5.0~135.0) ¡ãC

Temp coefficient

Adjustable

Calibration

May calibrate electrode constant or TDS switch coefficient.

support two-point calibration

Measuring mode

3 (continuous measurement, timed measurement and balance measuring mode)

Data storage

1500 data with time-and-date for GLP compliance (to display measuring result in diagram directly)

View, delete and print

Yes

Display

Touch, big LCD screen

Output

RS-232, USB

Software

1.1DC

Power

Universal power adapter (9V DC, 800mA, inside - positive, outside - negative)

Case outside serial No.

WXS-A009-1

Dimension (mm), Weight(kg)

250*195*100, 2

Gross Weight(kg)

4

Packing Size (mm)

(Carton Box)

370*310*340

¡¡ ¡¡

SR513 Lab Conductivity Meter (5 in 1)

Features and Applications:

- Be used for conductivity measuring of general water solution

- Plastic conductivity electrode with ATC, easy to use

- Economical bench-top conductivity meter

- Nice appearance, easy to use. It equips a flexible electrode holder, intelligent stirrer and a brief operation manual.

- Meter meets with the requirement of international GLP standards. It features up to automatic calibration, automatic temperature compensation, storage data, clock display, time measurement, RS232 output, functions setting and self-diagnose information etc.

- It adopts digital filter and step slipping technology to improve meter's response speed and repeatability.

- Meter has the only product serial number.

Dustproof and waterproof meter meets IP54 standards.

Measuring Parameters:

Conductivity, resistivity, TDS, salinity and temperature

Range:

Cond:0 to 200 mS/cm,be divided into five ranges

(0.00 to 20.00)¦ÌS/cm; (20.0 to 200.0)¦ÌS/cm;

(200 to 2000)¦ÌS/cm; (2.00 to 20.00)mS/cm;

(20.0 to 200.0)mS/cm

Res: (0 to 100)M¦¸¡¤cm; TDS: (0 to 100)g/L

Sal: (0 to 100)ppt    Temp: (-10 to 110)ºC

Accuracy:

Cond: ¡À1.0% full scale       Temp: ¡À0.5ºC

Other Parameters:

ATC: (0 to 50)ºC Storage

Data: 100 groups;

Communication Connector: RS-232;

Power: DC9V/300mA;  

Size & Weight: (160¡Á190¡Á70)mm/880g

Accessories:

1. 2301-M plastic conductivity electrode (K=1,ATC)

2. Model 602 flexible electrode holder

3. RS-232 communication software

¡¡

Model: SR515 Precision Conductivity Meter

Measuring Parameters: Conductivity, Resistivity, TDS, salinity and temperature

Features and Applications

- High precision bench-top conductivity meter

- ¡°CH¡± and ¡°USA¡± two series of standard solution can be setup, automatically recognizes eight kinds of conductivity

- Calibration solution.

- 18 ºC, 20 and 25 three kinds of reference ºC temperature can be setup.

- Inside setup with function of high purified water non-linearity automatic temperature compensation, suitable for accurate conductivity measurement for high purified water.

Specifications:

Range:  

Cond: 0 to 2000 mS/cm,be divided into five ranges

(0.00 to 20.00)¦ÌS/cm; (20.0 to 200.0)¦ÌS/cm;  

(200 to 2000)¦ÌS/cm; (2.00 to 20.00)mS/cm;  

(20.0 to 200.0)mS/cm;  (200 to 2000)mS/cm (k=10)

Res: (0 to 100)M¦¸¡¤cm; TDS: (0 to 100)g/L

Sal: (0 to 100)ppt  Temp: (-10 to 110) ºC  

Accuracy:  

Cond: ¡À0.5% full scale   

Temp: ¡À0.4 ºC

Other Parameters: 

ATC: (0 to 50) ºC Storage

Data: 600 groups; 

Communication Connector: RS-232; 

Power: DC9V/300mA; 

Size & Weight: (160¡Á190¡Á70)mm/880g

What's included: 

1. 2401-M conductivity electrode (K=1,ATC)

2. Model 602 flexible electrode holder

3. RS-232 communication software

¡¡ ¡¡

EC910 Conductivity/TDS/Salt/Temp. Meter

Main features:
* TFT color screen with graphic and text guides
* Equipped with a flexible electrode holder
* Multi-language operating system (English, Chinese, German, Italian and Spanish)

Technical Parameters:

Conductivity

Measuring range

Conductivity: 0~200.0mS/cm

TDS: 0.1mg/L~100 g/L

Salinity: 0~100 ppt

Resolution

0.1/1uS, 0.01/0.1mS

Accuracy

¡À1% FS ¡À 1 digit

Temp. compensation range

0 to 50 ºC (32 to 212 ºF), automatic or manual

Electrode constant

0.1 / 1 / 10 cm-1

Criterion temperature

15-30 ºC

Temp. compensation coefficient 0~10.00%/ ºC
Calibration 1~4 points automatic
Calibration standard USA/ CH
Calibration data checking Yes

Temperature:

Measuring range

-0~100.0 ºC; 32.0~212 ¡ãF

Resolution

0.1 ºC; 0.1/1 ¡ãF

Accuracy

¡À0.5 ºC ¡À 1 digit; ¡À0.9 ºF ¡À 1 digit

Function:

Display

TFT color display

Automatic hold

Yes

Data storage 100 sets
Self diagnosis information Yes
pH electrode connector BNC
Electrode holder 602 flexible holder
IP Rating IP54 water and dust proof
Electrode 2301T-F

Other Technical Parameters:

Power

DC9V

Size and weight

200¡Á220¡Á100mm/ 950g

¡¡ ¡¡

EC950 Conductivity/TDS/Salt/Temp. Meter

Main features
* TFT color screen with graphic and text guide
* Multifunctional test bench with intelligent stirrer and flexible electrode holder
* Multi-language operating system (English, Chinese, German, Italian and Spanish)

Technical Parameters:

Conductivity

Measuring range

Conductivity: 0~200.0mS/cm

TDS: 0.1mg/L~100 g/L

Salinity: 0~100 ppt

Resolution

0.1/1uS, 0.01/0.1mS

Accuracy

¡À1% FS ¡À 1 digit

Temp. compensation range

0 to 50 ºC (32 to 212 ºF), automatic or manual

Electrode constant

0.1 / 1 / 10 cm-1

Criterion temperature

15-30 ºC

Temp. compensation coefficient 0~10.00%/ ºC
Calibration 1~4 points automatic
Calibration standard USA/ CH
Calibration data checking Yes

Temperature:

Measuring range

-0~100.0 ºC; 32.0~212 ¡ãF

Resolution

0.1 ºC; 0.1/1 ¡ãF

Accuracy

¡À0.5 ºC ¡À 1 digit; ¡À0.9 ºF ¡À 1 digit

Function:

Display

TFT color display

Automatic hold

Yes

Data storage 100 sets
Self diagnosis information Yes
pH electrode connector BNC
Electrode holder 606 combination test bench (with stirrer)
IP Rating IP54 water and dust proof
Electrode 2401T-F

Other Technical Parameters:

Power

DC9V

Size and weight

360¡Á165¡Á400mm/ 1250g

¡¡ ¡¡

¡¡

Main features
* TFT color screen with graphic and text guides
* Conform to GLP data management standard, each group data includes time & date, ID of sample, electrode, and user
* Operation with password protection; support GLP printer
* Multi-language operating system (English, Chinese, German, Italian and Spanish)

EC9500 Conductivity/TDS/Salt/Res/Temp. Meter

Technical Parameters:

Conductivity

Measuring range

Conductivity: 0~2000mS/cm

TDS: 0.1mg/L~500 g/L

Salinity: 0~100 ppt

Resistivity: 0~20M¦¸▪cm

Resolution

0.01/0.1/1uS,0.01/0.1/1mS

Accuracy

¡À0.5% FS ¡À 1 digit

Temp. compensation range

0 to 50 ºC (32 to 212 ºF), automatic or manual

Electrode constant

0.1 / 1 / 10 cm-1

Criterion temperature

15-30 ºC

Temp. compensation coefficient 0~10.00%/ ºC
Calibration 1~4 points automatic
Calibration standard USA/ CH/ User
Calibration reminding Yes
Calibration data checking Yes
Measuring alarm Yes

Temperature:

Measuring range

-10~110.0 ºC; 14.0~230 ¡ãF

Resolution

0.1 ºC; 0.1/1 ¡ãF

Accuracy

¡À0.5 ºC ¡À 1 digit; ¡À0.9 ºF ¡À 1 digit

Function:

Display

TFT color display

Automatic hold

Yes

Date and time Yes
Data storage 1000 sets
Timing storage Yes
Self diagnosis information Yes
USB output Yes
GLP print Yes (printer optional)
External keypad Yes
pH electrode connector BNC
Electrode holder 606 combination test bench (with stirrer)
IP Rating IP54 water and dust proof
Electrode 2401T-F

Other Technical Parameters:

Power

DC9V

Size and weight

360¡Á165¡Á400mm/ 1250g

¡¡

TDS meter          EC/CF (conductivity), salinity meter          bench-top TDS/conductivity meter         Soil EC Tester