Gas Alarm/Detector series

For hand-held gas detector, please click here: gas detector

For gas valve, please click here: gas valve

For gas sensor, please click here: gas sensor

 

Combustible gas (Natural Gas/LPG/Coal Gas)          CO (Carbon Monoxide)          Multi-gas (CO+gas)

 

Model

Name

Technical Parameters 

TT-712NS

TT-712NV

Gas Leakage Detector (Independent)

TT-712NS

Semiconductor sensor
Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound& LED Flash alarm;
Alarm level: 10% ±5% LEL.
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 118.5*82*43mm .             
Execute criterion:GB15322;EN50194;UL1484

9V ordinary alkaline backup battery or 9V chargable back up battery (recommended ) optional

 

Gas Leakage Detector (Independent)

TT-712NV

Semiconductor sensor
Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound& LED Flash alarm;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve and exhaust fan;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 118.5*82*43mm .             
Execute criterion:GB15322;EN50194;UL1484

9V ordinary alkaline backup battery or 9V chargable back up battery (recommended ) optional

 

TT-712NSZ

TT-712NVZ

Gas Leakage Detector with LED display (Independent)

TT-712NSZ

Catalytic sensor, with digital LED display for concentration 
Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound& LED Flash alarm;
Alarm level: 10% ±5% LEL.
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 118.5*82*43mm .             
Execute criterion:GB15322;EN50194;UL1484

9V ordinary alkaline backup battery or 9V chargable back up battery (recommended ) optional

 

Gas Leakage Detector with LED display (Independent)

TT-712NVZ

Catalytic sensor, with digital LED display for concentration 
Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound& LED Flash alarm;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve and exhaust fan;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 118.5*82*43mm .             
Execute criterion:GB15322;EN50194;UL1484

9V ordinary alkaline backup battery or 9V chargable back up battery (recommended ) optional

 

TT-701S

TT-701R

TT-701N-AC

Gas Leakage Detector (Independent)

TT-701S

Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve or manipulator;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (wireless)

TT-701R

Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;wireless transmission;
Sending frequency: 433MHz/315MHz
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve or manipulator;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (Network)

TT-701N-AC

Operating voltage: 85-265V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve or manipulator;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

 

TT-701N-DC

TT-701LN-DC

 

Gas Leakage Detector (Network)

TT-701N-DC

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve or manipulator;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (Network low power consumption)

TT-701LN-DC

Low power consumption
Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Drivable accessaries: electromagnetic valve or manipulator;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (Network)

TT-705S

Working Voltage AC 220V
 Rated Power: 3W
 Warm-up Time:about 180S
 Alarm Indication:red LED flash
 Malfunction Indication:red/green LED on & beeper long buzz.
 Alarm Output:relay output(N.C/N.O)/sound & flash
 Alarm Sound:85dB within 3 meters
 Working Temperature:-10
+50
 Application:natural gas/LPG/LNG etc.
 Alarm Level:10% level
 Dimension:115*70*41mm
 Execute Criterion:GB15322-2003 , EN50194

Gas Leakage Detector (Network)

TT-705N-AC

Operating voltage: AC110V or 220V

Alarm output: Relay output;  sound &  flash alarm

Sound level: 85dB/3 meters

Installation: Wall mounted

Gas species:LPG&Natural gas

Alarm level:10%±5%LEL

Dimension: 115*72*41mm

Gas Leakage Detector (Network)

TT-705N-DC

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

Gas Leakage Detector (Network low power consumption)

TT-705LN-DC

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 115*72*41mm .             
Execute criterion:GB15322;EN50194;UL1484

TT-702S

TT-702R

TT-702N-AC

Gas Leakage Detector (Independent)

TT-702S

Operating voltage: 110V/220V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (Wireless)

TT-702R

Operating voltage: 110V/220V AC;  Wall mounted;
Alarm output: Sound&Flash alarm; Wireless transmission;
Sending frequency: 433MHz/315MHz
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (network)

TT-702N-AC

Operating voltage: 110V/220V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

 

TT-702N-DC

TT-702LN-DC

 

Gas Leakage Detector (network)

TT-702N-DC

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

Gas Leakage Detector (Network low power consumption)

TT-702LN-DC

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

TT-702FS

TT-702FR

 

Gas Leakage Detector (Independent)

TT-702FS

Operating voltage: 110V/220V AC;  Wall mounted;
Alarm output: Sound&Flash alarm;
Drivable accessaries: exhaust fan
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector
(Wireless)

TT-702FR

Operating voltage: 110V/220V AC;  Wall mounted;
Alarm output: Sound&Flash alarm; Wireless transmission;
Sending frequency: 433MHz/315MHz
Drivable accessaries: exhaust fan
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: 110*70*40mm .             
Execute criterion:GB15322;EN50194;UL1484

220V A.C. Network type, ordinary

 

TT-706N

TT-706LN

Gas Leakage Detector (Network)

TT-706N

Operating voltage: 12-24V DC;  ceiling mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: Φ104*51mm .             
Execute criterion:GB15322;EN50194;UL1484

 

Gas Leakage Detector (Network low power consumption)

TT-706LN

Operating voltage: 12-24V DC;  Wall mounted;
Alarm output: Sound&Flash alarm;Relay output;
Alarm level: 10% ±5% LEL.
Auto reset;
High Reliability sensor;
MCU processing adopted,SMT adopted,good stability
Malfunction auto-check indicator
Dimension: Φ104*51mm .             
Execute criterion:GB15322;EN50194;UL1484

 

TT-7012R wireless siren

This serien is used for wireless transmission for wireless gas alarm Model TT-701R, TT-702R.

 

TT-GH601 LPG 10%LEL
Key Specifications:

GH series gas leak alarm is a kind of wall-hung household gas alarm designed to detect the concentration of combustible and toxic gases or vapors, Provides visual and audible signals when the gas concentration reaches presetting level, remind you take prompt favorable action, you may start up other link equipment, ventilate gas or shut off gas supply to avoid fire, explosion, suffocation, and other evil accident
Alarms are available for liquefied petroleum gas (LPG), natural gas (methane), propane, hydrogen, town gas, smoke
Can be installed at home and any other similar place
Working voltage: AC2 20V +/- 15%, 50Hz or DC 12V
Target gas: combustible gas
Power consumption: 3W
Temperature: 0-55 deg. C
Humidity: < 95%
Response time: 30s automatic resume
Gas sampling: natural diffusion
Preset alarm point:
Combustible gas: 10%LEL
CO 150ppm
H2 1,000ppm
Alarm method: visual and audible
Alarm sound: 70dB
Weight: 270g
Dimensions (L x W x H): 137 x 75 x 49mm
Optional functions: relay output and gas shut off valve output

CE approved

 

Please be noted:

Question: I want to know what is life of electrochemical sensor and it is one time use or not?

Semiconductor gas sensor        5 years min.

Catalytic gas sensor                 3 years min.

Electrochemical gas sensor       5 years min.

Yes, they are one time use. When the sensor life is overdue, the user needs to contact us to replace the gas sensor or replace the whole gas detector unit.

 

( If you need user manual, E-catalogue or picture without watermark for above meters, please ask for at: xiushunjie@163.com)

 

For hand-held gas detector, please click here: gas detector

For gas valve, please click here: gas valve

For gas sensor, please click here: gas sensor