SRDL2000 CO2 Carbon dioxide, Temperature &
humidity Monitor; 3 in 1 Data logger
Features
•Super large LCD simultaneously display and log CO2 Level, Temperature,
Relative Humidity, Calendar (Y/M/D) and Time (clock)
•DIGITAL WALL MOUNTABLE/ DESKTOP TYPE!
•12700 data logging memory
•WARNING CARBON DIOXIDE LEVEL!
•Stable NDIR sensor for CO2 concentration
•NDIR (Non-Dispersive Infrared) WAVE GUIDE TECHNOLOGY WITH ABC
(Automatic Background Calibration)
•High and Low threshold setting
•ALARM OUTPUT DRIVE RELAY TO CONTROL SYSTEM
•Back light Function
•Recall MAX and MIN reading
•LONG TIME DRIFT COMPENSATION
•Comes with Power Adaptor (choose one from the available plug US/ UK/ AU/ EUR)
Specifications
Large LCD Display: 3.5¡±(8.9cm) LCD display with backlight
Logger mode: Key start/ stop, Immediately, Schedule, Real-time& Roll-over
Carbon Dioxide (CO2)
Range: 0~9999 (out of scale), Accuracy: ¡À50ppm ¡À5%rdg (0~2000)
Response time: 10sec
Temperature
Range: -10.0~70.0¡ãC(14~158¡ãF)
Resolution: 0.1¡ãC/¡ãF
Accuracy: ¡À0.6¡ãC/¡À0.9¡ãF(0~50¡ãC/32~122¡ãF), others ¡À1.2¡ãC
Humidity
Range: 0.1~99.9%
Resolution: 0.1%
Accuracy: ¡À3%(10~90%)
Logging Memory: 12700
Operating Condition: 0~50¡ãC,0~95%RH
Storage Condition: -20~60¡ãC,0~99%RH
Sensor life: 15years in normal comm. Environments with ABC on
Storage Temp: -40~70¡ãC(-40~158¡ãF)
Power Supply: AA Battery or 1A Output 9V AC Adaptor |
¡¡ |
¡¡ |
Functions
1).Display
carbon dioxide concentration and ratio by lcd.
2).Close/Open backlight by key.
3).Close/Open transfinite alarm by key.
4).Record
and check the maximum minimum value.
5).Set time
function. |
SRDL344 & SRDL344D CO2 Carbon dioxide, Temperature & humidity Monitor; 3
in 1 Data logger
Introduction
SRDL344 series CO2 monitor could measure the CO2 concentration, air
temperature, humidity. Poor indoor air quality is considered unhealthy
because it causes tiredness, loss of ability to concentrate, and even
illness. IAQ monitoring and survey, especially on CO2 level and air
ventilation become widely applied in public areas such as offices,
classrooms, factories, hospitals and hotels. It is also suggested in
regulations of industrial hygiene in some countries.
Technical Specification:
The power supply |
5VDC¡À10% |
Average power |
2.5W |
Detection of gas |
Carbon dioxide, NDIR (Non-Dispersive Infra-Red) |
Measuring range |
CO2: 0-9999ppm
Temperature: -40~80ºC
Humidity: 0~100%RH |
Accuracy |
CO2: ¡À50ppm +5%
Temperature: ¡À0.5ºC
Humidity: ¡À3%RH |
Resolution |
CO2: 1ppm
Temperature: 0.1ºC
Humidity: 0.1%RH |
Response Time |
<30 Second |
Preheating Time |
<5 Minutes |
Data Logger
(only for SRDL344D) |
a. Memory: 12332 readings
b. Used as a u-disk
c. Generate TXT logging file |
Charging |
Input: AC100-240V Output: 5V,2A |
Operating Environment |
0~50ºC
(32~122¡ãF);
0~95%RH |
Store Condition |
-20~50ºC,
0~90%RH, A standard atmospheric pressure |
Weigh/Size |
221g/126mm*84mm*36mm |
|
¡¡ |
¡¡ |
|
SR7810-CO2 series CO2 temperature and humidity 3 in 1 monitor
with SD card
Features:
Measuring: Temperature, Humidity, CO2
Accuracy: Temperature: +/- 0.5¡ãC, Humidity: +/- 3%RH ,CO2: +/-
(50ppm+3%)
Sensor: Humidity: Capacitive CO2:NDIR
Correspond time: CO2: (T90) <60s; Temperature and humidity:
1/e(63%)change, Slow flow rates<10s
Alarm: Sound and light alarm
Operating: Touch buttons,
USB interface
Input power: 5VDC
Power consumption: 1.5W
Warm-up time: 2 minutes, and for the first time 2 hours
Use environment: -10¡ª50degree, 0--95%(No condensation)
Housing: IP40
Size: 125*85*30mm |
Specification:
Model |
SR7810-CO2 |
SR7810-CO2/SD |
SR7810-CO2/SD-B |
Measuring range |
Temperature:-20 ~ 50¡ãC
Humidity:0~100%
CO2:300~3000ppm |
Temperature:-20 ~ 50¡ãC
Humidity:0~100%
CO2:300~3000ppm |
Temperature:-20 ~ 50¡ãC
Humidity:0~100%
CO2:300~3000ppm |
Data recording SD card function |
NO |
Up to 100,0000data |
Up to 100,0000data |
Bluetooth function |
NO |
NO |
YES |
Export data |
NO |
TXT |
TXT |
|
¡¡ |
¡¡ |
9-in1 High-end
Intelligent Air Detector
Accurate Detection for formaldehyde.
Accurate Detection for TVOC and benzene.
PM 2.5
Air quality monitoring.
PM 10
Air quality monitoring.
Real
time temperature monitoring
Real
time humidity monitoring.
Air
quality Record and analysis.
24
hours a day for Air detecting.
Light
sensor for save power. |
SR8630 High sensitive formaldehyde
detecto with good quality of LCD
Technical Parameter
Display Mode:
High-definition liquid crystal display (LCD)
Distinguishability:
240*320
Temperature Range:
0¡ãC~45¡ãC
Humidity Range:
0%~99%
Product Dimension:
146*99*65mm
Product Weight:
225g
Battery
Capacity:
2000mAh
Lithium Battery
Input:
5.0V/500mA
Charging Temp.:
-10¡ãC~45¡ãC
Operation Environment
Atmospheric Pressure:
86Kpa~106Kpa
Humidity Range:
20%~85%
Working Temp.:
-10¡ãC~45¡ãC
Storage Temp.:
-20¡ãC~50¡ãC
HCHO
Test Item:
HCHO in the air
Test Range:
0.000~1.999 mg/m3
Detection Technique:
Electrochemistry
Sensing Technology
Sample Mode:
Diffusion Type
Density Unit:
mg/m3
TVOC
Test Item:
TVOC in the air£¨Including
benzene£©
Test Range:
0.000~9.999 mg/m3
Detecting Time:
5 minutes
Detection Technique:
Semiconductor Sensing Technology
Sample Mode:
Diffusion Type
Density Unit:
mg/m3
PM2.5/PM10 with imported
sensor
Detection Technique:
Laser scattering
Test the particle diameter:
2.5¦Ìm¡¢10¦Ìm
Sampling Time:
3 seconds
Detection mode:
Density (Per liter)
Detection range:
0~999¦Ìg/
m3 |
¡¡ |
¡¡ |
|
SR8701 Formaldehyde Monitor,
HCHO+Temp+RH+Calendar
4-in-1 Monitor
Gas Tested |
HCHO In The Air |
Measuring Range |
0-3mg/m3 |
Resolution |
0.01mg/m3 |
Minimum Reading |
0.01mg/m3 |
Basic Error |
+/-0.03+/-5% |
Response Time |
< 30 Seconds |
Sensor Type |
Electrochemical HCHO Sensor |
Rechargeable Battery |
YES |
Buzzer Alarm Setup |
YES |
MAX, AVG, Data Hold |
YES |
Low Battery Indication |
YES |
LCD Backlight |
YES |
Environment
Testing |
¡¡ |
Temperature, Relative
Humidity |
0~50ºC,32~122¡ãF;10~90%RH |
Temp. RH Accuracy |
+/-1ºC/¡ãF 5%RH |
Storage Environment |
-10~80ºC,-14~176¡ãF;10~75%RH |
Power |
3x3.6V NIMH Batteries |
Size |
91.5*64.8*135mm |
Weight |
152g |
|
¡¡ |
¡¡ |
|
SR8702 Carbon Dioxide
Monitor,
CO2+Temp+RH+Calendar
4-in-1 Monitor
Gas Tested |
CO2 In The Air |
Measuring Range |
0~2000ppm |
Resolution |
1ppm |
Minimum Reading |
1ppm |
Basic Error |
+/-(50ppm +3% Of Measured Value) |
Response Time |
< 30 Seconds |
Sensor Type |
NDIR CO2
Gas Sensor |
Rechargeable function |
YES |
Buzzer Alarm Setup |
YES |
MAX, AVG, Data Hold |
YES |
Low Battery Indication |
YES |
LCD Backlight |
YES |
Environment
Testing |
¡¡ |
Temperature, Relative
Humidity |
0~50ºC,32~122¡ãF;10~90%RH |
Temp. RH Accuracy |
+/-1ºC/¡ãF 5%RH |
Storage Environment |
-10~80ºC,-14~176¡ãF;10~75%RH |
Power |
Battery Excluded |
Size |
91.5*64.8*135mm |
Weight |
156.5g |
|
¡¡ |
¡¡ |
|
SR8703 Air Quality Detector,
PM2.5+PM10+Temp+RH 4-in-1 Monitor
Features:
Rechargeable function: YES
Buzzer Alarm Setup: YES
MAX, MIN Data Hold: YES
Low Battery Indication: YES
LCD Backlight: YES
Specifications:
Gas Tested: PM2.5, PM10 In The Air
Measuring Range: (0~5000) ug/m3
Resolution: 1 ug/m3
Minimum Reading: 1 ug/m3
Minimum diameter of tested particle: 0.3um
Response Time: < 10 Seconds
Measuring principle: Laser
scattering
Environment Testing:
Temperature: 0~50ºC/ 32~122¡ãF;
Relative Humidity: 10~90%RH
Accuracy: Temperature: +/-1ºC/¡ãF;
Humidity: 5%RH
Storage Environment: -10~80ºC,-14~176¡ãF;10~75%RH
Power: 3*1.2V AAA rechargeable NiMH battery or 5V 1A power
adapter
Size: 91.5*64.8*135mm
Weight: 152g (not including battery) |
¡¡ |
¡¡ |
|
SR8704 Multifunctional Air Quality
Detector,
PM2.5+PM10+HCHO+Temp+RH 5-in-1 Monitor
Features:
Rechargeable function: YES
Buzzer Alarm Setup: YES
MAX, MIN Data Hold: YES
Low Battery Indication: YES
LCD Backlight: YES
Specifications:
Gas Tested: PM2.5, PM10 and HCHO In
The Air
Measuring Range: PM2.5, PM10: (0~5000) ug/m3; HCHO: (0~1) mg/m3
Resolution: PM2.5, PM10: 1 ug/m3; HCHO: 0.01 mg/m3
Minimum Reading: PM2.5, PM10: 1 ug/m3; HCHO: 0.01 mg/m3
Minimum diameter of tested particle: 0.3um
Basic Error for HCHO: £¼¡À5%FS
Response Time: < 10 Seconds
Measuring principle: PM2.5, PM10:
Laser scattering; HCHO: Electrochemical
Environment Testing:
Temperature: 0~50ºC/ 32~122¡ãF;
Relative Humidity: 10~90%RH
Accuracy: Temperature: +/-1ºC/¡ãF;
Humidity: 5%RH
Storage Environment: -10~80ºC,-14~176¡ãF;10~75%RH
Power: 3*1.2V AAA rechargeable NiMH battery or 5V 1A power
adapter
Size: 91.5*64.8*135mm
Weight: 152g (not including battery) |
¡¡ |
¡¡ |
|
SR8700A Combustible Gas Detector
1. Response time:
2
seconds
2. Warm up time: 60
seconds approx( 25ºC,
60% RH environment)
3. Continuous operation time: 8
hours (varying with operating status)
4. Low battery indication: :3¡À0.2V
5. Operation temperature: 0~52ºC
6. Adjustable detection control
7. Reset button on the probe handle
8. Constant power indication
9. Power: 3*1.5V
LR14 Battery
10. Unit size: 76*49*220MM
11. Standard quantity per carton: 20PCS
12. Standard carton size: 51.1*37.4*28.5CM
13. Standard carton gross weight: 14.4KG
|
¡¡ |
¡¡ |
|
SR8705 Carbon Monoxide
Meter,
CO+Temp
2-in-1 Meter
Gas Tested |
CO In The Air |
Measuring Range |
0-1000ppm |
Resolution |
1ppm |
Minimum Reading |
1ppm |
Basic Error |
+/-5%(f.s),+/-10ppm |
Response Time |
60 Seconds |
Sensor Type |
Electrochemical CO Sensor
|
Buzzer Alarm Setup |
YES |
Review Of Max And Min Reading |
YES |
Setting Up Range Of Co Content |
YES |
MAX, AVG, Data Hold |
YES |
Auto Power Off |
YES |
Low Battery Indication |
YES |
LCD Backlight |
YES |
Environment
Temperature Test Range |
0~50ºC;
32-122¡ãF |
Accuracy |
+/-2ºC/¡ãF |
Storage Environment |
-10~80ºC;
-14~176¡ãF; 10-75%RH |
Power |
2x1.5V AAA Batteries |
Measurements |
55.7*29.9*135.5mm |
Weight |
104g |
|
¡¡ |
¡¡ |
|
SR8706 Ammonia Gas Detector, NH3 + Temp
2-in-1 Meter
Gas Tested |
NH3 In The Air |
Measuring Range |
0-100ppm |
Resolution |
1ppm |
Minimum Reading |
1ppm |
Basic Error |
¡Ü50ppm: ¡À5ppm;
(50~100)ppm: ¡À10% |
Response Time |
<120 Seconds |
Sensor Type |
Electrochemical NH3 Sensor
|
Buzzer Alarm Setup |
YES |
Setting Up Range Of NH3 Content |
YES |
MAX, AVG, Data Hold |
YES |
Auto Power Off |
YES |
Zero Calibration |
YES |
LCD Backlight |
YES |
Environment
Temperature Test Range |
0~40ºC;
32-104¡ãF |
Accuracy |
+/-2ºC/¡ãF |
Storage Environment |
0~40ºC;
32~104¡ãF; 10-90%RH |
Power |
2x1.5V AAA Batteries |
Measurements |
55.7*29.9*135.5mm |
Weight |
104g |
|
¡¡ |
¡¡ |
|
SR55M8 Mini Carbon Monoxide Meter
Description:
Carbon monoxide meter detects the presence of carbon monoxide (CO)
and measures concentrations between 1-1000 parts per million (PPM).
The meter indicates the presence of CO by a reading on the LCD and a
beeper tone.
Specifications:
Sensor |
Stabilized electrochemical Gas-specific |
Measurement Range |
0~1000 PPM |
Accuracy |
5% or 10PPM |
Measurement Resolution |
1PPM |
Response Time |
<30S |
Zero Drift |
<5PPM |
Repeatability |
¡À2% |
Fast sampling Time |
2 times/second |
Long-time Stability |
<5%/year |
Operating Conditions |
-20~50¡ãC;15~90%RH |
Storage Conditions |
-30~50¡ãC; 0~80%RH |
Audible Alarm |
can set upper limit |
Auto Power Off |
after 15 minutes of inactivity |
Typical Sensor Life |
about 5 years |
Dimension (L*W*H) |
175 * 55 * 38mm |
Weight |
90g |
Accessories |
User¡¯s manual,9V battery, carrying case, gift box |
|
¡¡ |
¡¡ |
|
HST80 Pen type Gas
Detector
Features: -Sensitive, jamproof; -Best for home application;
-Three types of indications, easy operation; -long battery life;
-auto shutdown.
MODEL |
HST80 |
Detection |
natural gas, LPG, goal gas and etc.. |
Sensor |
planar semiconductor |
Warm up time |
within 60 seconds |
Rnage of detection |
CH4: 0 ~ 100% LEL |
Alarm Frequency |
2.713kHz / 30ms |
2.713kHz / 100ms |
Range of alarm |
~2% LEL (LED Yellow) |
~10% LEL (LED Red) |
Alarm time |
within 20 seconds |
Alarm mode |
LED, buzzer |
Working temperature |
-20C ~ 70C |
Working humidity |
less than 90% RH |
Power source |
AA 1.5V * 2 |
Dimension |
220 * 20 * 20 mm |
Weight |
approx. 80g |
|
¡¡ |
¡¡ |
|
¡¡
HST8800A+ Combustible
Gas detector This highly reliable broad range combustible gas detector
HST8800A+ is an extremely useful tool in any environment where
gasoline, propane, natural gas, fuel oil and many other
explosive gases may be present. As a combustible gas or vapor source is approached, an audible
signal increases in frequency and the red lights illuminate in
sequence, to show the intensity of the leak. Now you can see and
hear your way to pinpointing dangerous leaks. The unique
flexible probe gives you access to gas leaks in hard to reach
places. Features: -Ergonomic model, nice handheld touch;
-LCD and buzzer alarms; -Self faulty detection of sensor during startup;
-Li cells employed, recharing anywhere.
MODEL |
HST8800A+ |
Detection |
natural gas, LPG, artificial goal gas
and etc.. |
Sensor |
planar semiconductor |
Warm up time |
less than 60 seconds |
Alarm |
20Hz ~ 5KHz |
Range of alarm |
~1% LEL LED1 flashing, without buzzer |
~2% LEL LED2 flashing, with buzzer |
~5% LEL LED3 flashing, with buzzer |
~10% LEL LED4 flashing, with buzzer |
~20% LEL LED5 flashing, with buzzer |
Alarm mode |
LED, buzzer |
Working temperature |
-20C ~ 70C |
Working humidity |
less than 90% RH |
Power source |
Li cell 3.7V 1100mA/h |
Indication of charge |
10% red LED1 |
20% red LED2 |
30% red LED3 |
40% red LED4 |
50% red LED5 |
Indication of sensitivity |
Level 0, red LED3 |
Level -1, red LED2 |
Level -2, red LED0 |
Level +1, red LED4 |
Level +2, red LED5 |
Dimension |
275 * 70 * 30 mm |
Weight |
approx. 220g |
|
¡¡ |
¡¡ |
|
¡¡
Combustible Gas Meter HST880
Features
-
Easy to read 6999 count
backlit displays natural
gas, LPG, goal gas levels
from 0 to 6000ppm
-
record logging (3 sets)
-
visible and audible alarm >=
500ppm
-
zero point adjustable, gas
provision stored permanently
-
auto power off, buzzer
raised on 30 seconds before
power off
-
3.7V 650mAh Li cells
employed, recharging
anywhere
-
data hold
-
low battery warning
MODEL |
HST880 |
Detection |
natural gas, LPG, goal
gas. |
Sensor |
thermal linear
semiconductor sensor |
Range of detection |
0 ~ 6000ppm |
Bootup time |
<= 20
seconds |
Alarm frequency |
200Hz ~ 5kHz |
Range of alarm |
>= 500ppm
|
Alarm mode |
LED, buzzer |
Working temperature |
0¡ãC ~ 50¡ãC |
Working humidity |
under 90% RH |
Power Source |
Li cell 3.7V
650mA/h |
Battery Indication |
LCD
displayed |
Auto Power Off |
10 minutes
after standby (buzzer alarm in last 30 seconds) |
Dimension |
275 * 70 *
30 mm |
Weight |
approx. 220g |
|
¡¡ |
¡¡ |
|
¡¡
Carbon Monoxide Meter HST881
Features
-
Easy to read 6999 count
backlit displays carbon
monoxide gas levels from 0
to 1000ppm
-
record logging (3 sets)
-
visible and audible alarm >=
40ppm
-
zero point adjustable, gas
provision stored permanently
-
auto power off, buzzer
raised on 30 seconds before
power off
-
3.7V 650mAh Li cells
employed, recharging
anywhere
-
data hold
-
low battery warning
MODEL |
HST881 |
Detection |
carbon monoxide (CO) |
Sensor |
electrical chemistry
sensor |
Bootup time |
<= 20
seconds |
Range of detection |
0 ~ 1000ppm |
Resolution |
1ppm |
Accuracy |
5% or 10ppm |
Alarm frequency |
200Hz ~ 5kHz |
Range of alarm |
>= 40ppm
|
Alarm mode |
LED, buzzer |
Working temperature |
0¡ãC ~ 50¡ãC |
Working humidity |
under 90% RH |
Power Source |
Li cell 3.7V
650mA/h |
Battery Indication |
LCD
displayed |
Auto Power Off |
10 minutes
after standby (buzzer alarm in last 30 seconds) |
Dimension |
275 * 70 *
30 mm |
Sensor Life time |
>= 5 years |
Weight |
approx. 220g |
|
¡¡ |
¡¡ |
¡¡ |
SPD200B/CO Gas detector of Carbon
Monoxide Measurement display: displays with 4 digit LCD
Operation temperature: -10~50¡ãC (14~122¡ãF) Storing temperature: 0~40¡ãC(32~104¡ãC)
Operation humidity: 0~99%RH (relative humidity) Storing humidity: 20%~80% RH (relative humidity) Measuring range: 0~1000PPM
Resolution: 1PPM Measurement error: ¡À5% Over measurement range display: --OL-- Alarming method: acousto-optic alarming
Working principle of the sensor: electrochemistry sensor The service life of the sensor: 2 years (it can be then
replaced) Power supply: 3¡Á1.5V AAA alkaline batteries Battery service life: about 100 hours of continuous use (when
the backlight is off). Size: 172¡Á51¡Á26 (mm)
¡¡ |
¡¡ |
¡¡ |
¡¡ |
SPD201/O2 Gas detector of Oxygen,
OXYGEN GAS ALARM DETECTOR Measurement display: displays 4 digit LCD
Operation temperature: -10~40¡ãC (14~104¡ãF) Storing temperature: 0~30¡ãC (32~86¡ãF)
Operation humidity: 0~99%RH (relative humidity) Storing humidity: 20%~80% RH (relative humidity) Measuring range: 0~25%(VOL)
Resolution: 0.1 %( VOL) Measurement error: ¡À0.5% Over measurement range display: --OL-- Alarming method: acousto-optic alarming
Working principle of the sensor: source cell sensor The service life of the sensor: 2 years (it can then be
replaced) Power supply: 3¡Á1.5V AAA alkaline batteries Battery service life: about 100 hours of continuous use (when
the backlight is off). Size: 172¡Á51¡Á26 (mm)
|
¡¡ |
¡¡ |
|
SPD202/Ex COMBUSTIBLE GAS ALARM
DETECTOR
SPD202
combustible gas detector can be used in hazardous
areas indoors and outdoors, where combustible gas is produced,
stored, used, etc., such as chemical,
petroleum, metallurgy, oil depot,
LPG (Liquefied Petroleum Gas) station ,
pharmaceutical, gas transmission and distribution, etc. to
detect the leakage and show the leaking concentration with a
digital display. This device can set two-level alarming value.
The detector can raise the acousto-optic alarming when the
detected concentration reaches the preset value.
1)
Detecting principle: catalytic
combustion
2)
Detected gas: combustible gas
3)
Measurement range: 0-100% LEL (LEL:
Low Explosion Level - the lowermost concentration of combustible
gas to generate an explosion in air when meeting a naked flame)
4)
Resolution: 0.1%
5)
Error: ¡À2%
6)
Response time: <30s
7)
Operation temperature: -10ºC¡«60ºC
8)
Operation humidity: <99%RH
9)
Display mode: digital display with large LCD
screen
10)
Alarming method: acousto-optic alarming
11)
Power supply: 4¡Á1.5V AA batteries
12)
Current:
<110mA
(measuring status)
<15mA (non-measuring status)
|
¡¡ |
¡¡ |
¡¡
|
MODEL:
HSTDX70
CO
Single
Gas detector of
carbon monoxide
1. General
HSTDX70
is a kind of single gas or multiple gas detector/ alarm which
can be optionally equipped with oxygen sensor, combustible gas
sensor and any two or four sensors of different noxious gases,
or a single gas sensor.
HSTDX70
has a very clear and large LCD with audible and visible alarm,
and can detect any dangerous gas and send alarm to the operator
in time for prevention even in very inimical work environment.
2. Technical performance and parameters
Features:
-
Smart, portable and firm
-
Audible and visible alarm
-
Large screen digital and character display, instantaneous value,
peak value and mean value available
-
Self-checking for displaying, battery, sensor,
audible and visible alarm at startup
-
Regular light flashing and audible indication
-
Distinct audible alarm
-
Low maintenance cost
-
1 kind of gas detecting supported
Technical performance and parameters
Gas for detect:
carbon monoxide in the air (CO)
Range:0-999ppm
Precision:
<¡À 5% (F.S)
Least count:
1ppm/0.1ppm Response time: ¡Ü 25 sec
lithium ion rechargeable battery, 3.6V
Battery working period: 15 hours uninterrupted (combustible gas)
About 200 hours (except
combustible gas)
Sensor service life: 3 years for combustible gas sensor, 2 years
for oxygen and noxious gas sensor
Display: large screen LCD
Alarm: audible and visible alarm
Direct reading: instantaneous value, peak value, battery
voltage, TWA, STEL
Ex-mark: Ex ibdIICT3
Protection degree: IP45
Work
temperature: -10~40ºC
Work
humidity: 5~90% RH
Size: 126mm (L) x 66mm (W) x 32mm (H)
Weight: 220g (with charger) |
¡¡ |
¡¡ |
|
MODEL:
HSTDX70
CO2
Single
Gas detector of
carbon dioxide
1. General
HSTDX70
is a kind of single gas or multiple gas detector/ alarm which
can be optionally equipped with oxygen sensor, combustible gas
sensor and any two or four sensors of different noxious gases,
or a single gas sensor.
HSTDX70
has a very clear and large LCD with audible and visible alarm,
and can detect any dangerous gas and send alarm to the operator
in time for prevention even in very inimical work environment.
2. Technical performance and parameters
Features:
-
Smart, portable and firm
-
Audible and visible alarm
-
Large screen digital and character display, instantaneous value,
peak value and mean value available
-
Self-checking for displaying, battery, sensor,
audible and visible alarm at startup
-
Regular light flashing and audible indication
-
Distinct audible alarm
-
Low maintenance cost
-
1 kind of gas detecting supported
Technical performance and parameters
Gas for detect:
carbon dioxide in the air (CO2)
Range:0-5000ppm
(standard)
(Range can be customized as
customer's request)
Precision:
<¡À 5% (F.S)
Least count:
0.01ppm Response time: ¡Ü 50 sec
lithium ion rechargeable battery, 3.6V
Battery working period: 15 hours uninterrupted (combustible gas)
About 200 hours (except
combustible gas)
Sensor service life: 3 years for combustible gas sensor, 2 years
for oxygen and noxious gas sensor
Display: large screen LCD
Alarm: audible and visible alarm
Direct reading: instantaneous value, peak value, battery
voltage, TWA, STEL
Ex-mark: Ex ibdIICT3
Protection degree: IP45
Work
temperature: -10~40ºC
Work
humidity: 5~90% RH
Size: 126mm (L) x 66mm (W) x 32mm (H)
Weight: 220g (with charger) |
¡¡
Note: Besides
above stated CO2 and CO, HSTDX70 can also detect
any one/single
of the gas from below table.
Gas for detect |
Range |
Precision |
Least count |
Response time |
Oxygen (O2) |
0-30%Vol |
£¼¡À5% (F.S) |
0.1%Vol |
¡Ü 15 sec |
Combustible gas (Ex) |
0-100%LEL |
£¼¡À5% (F.S) |
1%LEL |
¡Ü 5 sec |
Carbon monoxide (CO) |
0-999ppm |
£¼¡À5% (F.S) |
1ppm |
¡Ü 25 sec |
Hydrogen sulphide (H2S) |
0-100.0ppm |
£¼¡À5% (F.S) |
1ppm |
¡Ü 30 sec |
Sulfur dioxide (SO2) |
0-100.0ppm |
£¼¡À5% (F.S) |
0.1ppm |
¡Ü 30 sec |
Nitrogen monoxide (NO) |
0-250ppm |
£¼¡À5% (F.S) |
1ppm |
¡Ü 60 sec |
Nitrogen dioxide (NO2) |
0-20ppm |
£¼¡À5% (F.S) |
0.1ppm |
¡Ü 25 sec |
Chlorine (Cl2) |
0-20ppm |
£¼¡À5% (F.S) |
0.1ppm |
¡Ü 30 sec |
Ammonia (NH3) |
0-100ppm |
£¼¡À5% (F.S) |
1ppm |
¡Ü 50 sec |
Hydrogen (H2) |
0-1000ppm |
£¼¡À5% (F.S) |
1ppm |
¡Ü 60 sec |
Hydrogen cyanide (HCN) |
0-50ppm |
£¼¡À5% (F.S) |
0.1ppm |
¡Ü 200 sec |
Hydrogen chloride (HCl) |
0-20ppm |
£¼¡À5% (F.S) |
0.1ppm |
¡Ü 60 sec |
Carbon dioxide (CO2) |
0-5000ppm |
£¼¡À5% (F.S) |
0.01ppm |
¡Ü 50 sec |
Hydrofluoric acid (HF) |
0-10ppm |
£¼¡À3% (F.S) |
0.1ppm |
¡Ü 50 sec |
Nitrogen (N2) |
70-100%Vol |
£¼¡À5%(F.S)
|
0.1%Vol |
¡Ü 30 sec |
|
¡¡ |
¡¡ |
|
MODEL:
HSTDX80
Gas
detector of multi-gas
1. General
HSTDX80
is a kind of single gas or multiple gas detector/ alarm which
can be optionally equipped with oxygen sensor, combustible gas
sensor and any two or four sensors of different noxious gases,
or a single gas sensor.
DX80
has a very clear and large LCD with audible and visible alarm,
and can detect any dangerous gas and send alarm to the operator
in time for prevention even in very inimical work environment.
2. Technical performance and parameters
Features:
-
Smart, portable and firm
-
Audible and visible alarm
-
Large screen digital and character display, instantaneous value,
peak value and mean value available
-
Self-checking for displaying, battery, sensor,
audible and visible alarm at startup
-
Regular light flashing and audible indication
-
Distinct audible alarm
-
Low maintenance cost
-
1, 2, 3, 4 kinds of gas detecting supported
from below table.
Main technical
indexes:
Gas for detect |
Range |
Precision |
Least count |
Response time |
Oxygen (O2) |
0-30%Vol |
£¼¡À5%
(F.S) |
0.1%Vol |
¡Ü 15 sec |
Combustible gas (Ex) |
0-100%LEL |
£¼¡À5%
(F.S) |
1%LEL |
¡Ü 5 sec |
Carbon monoxide (CO) |
0-999ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 25 sec |
Hydrogen sulphide (H2S) |
0-100.0ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 30 sec |
Sulfur dioxide (SO2) |
0-100.0ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Nitrogen monoxide (NO) |
0-250ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Nitrogen dioxide (NO2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 25 sec |
Chlorine (Cl2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Ammonia (NH3) |
0-100ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 50 sec |
Hydrogen (H2) |
0-1000ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Hydrogen cyanide (HCN) |
0-50ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 200 sec |
Hydrogen chloride (HCl) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 60 sec |
Carbon dioxide (CO2) |
0-5000ppm |
£¼¡À5%
(F.S) |
0.01ppm |
¡Ü 50 sec |
lithium ion rechargeable battery, 3.6V
Battery working period: 15 hours uninterrupted (combustible gas)
About 200 hours (except
combustible gas)
Sensor service life: 3 years for combustible gas sensor, 2 years
for oxygen and noxious gas sensor
Display: large screen LCD
Alarm: audible and visible alarm
Direct reading: instantaneous value, peak value, battery
voltage, TWA, STEL
Ex-mark: Ex ibdIICT3
Protection degree: IP45
Work
temperature: -10~40ºC
Work
humidity: 5~90% RH
Size: 126mm (L) x 66mm (W) x 32mm (H)
Weight: 220g (with charger)
|
¡¡ |
¡¡ |
|
MODEL:
HSTDX90
1. General
HSTDX90
is a kind of superior performance complex gas detection alarm,
which can simultaneously detect EX, oxygen, carbon monoxide,
hydrogen sulfide, or other gas, it is used for safety
checking before entering into a dangerous conditions or confined
space at industrial.
HSTDX90
has a very clear and large LCD with audible and visible alarm,
and can detect any dangerous gas and send alarm to the operator
in time for prevention even in very inimical work environment
HSTDX90
can detect Housing made of high strength engineering materials,
composite elastic rubber materials from refined, high strength,
feel good, and the waterproof, dust-proof, explosion-proof.
2. Technical performance and parameters
Features:
- Import sensor, stable and reliable performance - The use of high-strength ABS plastic, composite materials,
elastic rubber shell - Sound, vibration, and the shade of red, yellow, two-alarm - Large screen digital, character display, instantaneous, peak,
average shows - Very low maintenance costs
- Can support any one or four of the gas
detection from below table.
Main technical
indexes:
Gas for detect |
Range |
Precision |
Least count |
Response time |
Oxygen (O2) |
0-30%Vol |
£¼¡À5%
(F.S) |
0.1%Vol |
¡Ü 15 sec |
Combustible gas (Ex) |
0-100%LEL |
£¼¡À5%
(F.S) |
1%LEL |
¡Ü 5 sec |
Carbon monoxide (CO) |
0-999ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 25 sec |
Hydrogen sulphide (H2S) |
0-100.0ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 30 sec |
Sulfur dioxide (SO2) |
0-100.0ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Nitrogen monoxide (NO) |
0-250ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Nitrogen dioxide (NO2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 25 sec |
Chlorine (Cl2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Ammonia (NH3) |
0-100ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 50 sec |
Hydrogen (H2) |
0-1000ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Hydrogen cyanide (HCN) |
0-50ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 200 sec |
Hydrogen chloride (HCl) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 60 sec |
Carbon dioxide (CO2) |
0-5000ppm |
£¼¡À5%
(F.S) |
0.01ppm |
¡Ü 50 sec |
Methane (CH4) |
0-100%Vol |
£¼¡À5% (F.S) |
0.1%Vol |
¡Ü 20 sec |
lithium ion rechargeable battery, 3.6V
Battery working period: 15 hours uninterrupted (combustible gas)
About 200 hours (except
combustible gas)
Sensor service life: 3 years for combustible gas sensor, 2 years
for oxygen and noxious gas sensor
Display: large screen LCD
Alarm: sound, vibration, and both red and yellow colored light
alarm
Direct reading: instantaneous value, peak value, battery
voltage, TWA, STEL
Ex-mark: Ex ibdIICT3
Protection degree: IP45
Work
temperature: -10~40ºC
Work
humidity: 5~90% RH
Size: 130mm (L) x 70mm (W) x 32mm (H)
Weight: 210g (with charger) |
¡¡ |
¡¡ |
|
MODEL: HSTDX60
Gas detector with
external pump
Features: * Smart, portable and firm
* Audible and visible alarm
* Large screen digital and character display, instantaneous
value, peak value and mean value available * Self-checking for displaying, battery, sensor, audible and
visible alarm at startup * Regular light flashing and audible indication
* Distinct audible alarm * Low maintenance cost * 1, 2, 3 or 4 kinds of gas detecting supported
Technical parameter: Comes with a suction pump can be tens of meters from the outer
gas inhalation apparatus were Detection mode: gaseous diffusion Battery: lithium ion
rechargeable battery, 3.6V Battery working period: 15 hours uninterrupted (combustible gas) About 200 hours (except combustible gas) Sensor work principle: electrochemistry mode for oxygen and
noxious gas; catalytic combustion mode for combustible gas Sensor service life: 3 years for combustible gas sensor, 2 years
for oxygen and noxious gas sensor Display: large screen LCD Alarm: audible and visible alarm Direct reading: instantaneous value, peak value, battery
voltage, TWA, STEL Ex-mark: Ex ibdIICT3 Protection degree: IP45 Work temperature: -10~40ºC Work humidity: 5~90% RH Size: 126mm (L) x 66mm (W) x 32mm (H) Weight: 220g (with charger)
Main
technical indexes:
Gas for detect |
Range |
Precision |
Least count |
Response time |
Oxygen (O2) |
0-30%Vol |
£¼¡À5%
(F.S) |
0.1%Vol |
¡Ü 15 sec |
Combustible gas (Ex) |
0-100%LEL |
£¼¡À5%
(F.S) |
1%LEL |
¡Ü 5 sec |
Carbon monoxide (CO) |
0-999ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 25 sec |
Hydrogen sulphide (H2S) |
0-100.0ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 30 sec |
Sulfur dioxide (SO2) |
0-100.0ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Nitrogen monoxide (NO) |
0-250ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Nitrogen dioxide (NO2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 25 sec |
Chlorine (Cl2) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 30 sec |
Ammonia (NH3) |
0-100ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 50 sec |
Hydrogen (H2) |
0-1000ppm |
£¼¡À5%
(F.S) |
1ppm |
¡Ü 60 sec |
Hydrogen cyanide (HCN) |
0-50ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 200 sec |
Hydrogen chloride (HCl) |
0-20ppm |
£¼¡À5%
(F.S) |
0.1ppm |
¡Ü 60 sec |
Hydrogen phosphide (PH3) |
0-5-1000ppm |
£¼¡À5%
(F.S) |
0.01/1ppm |
¡Ü 25 sec |
Carbon dioxide (CO2) |
0-5000ppm |
£¼¡À5%
(F.S) |
0.01ppm |
¡Ü 50 sec |
(Range can be customized as customer's request) |
¡¡ |
¡¡ |
|
HSTDX50 CH2O Detector, Formaldehyde Detector
1.
summarize
HSTDX50 series portable intelligent
gas detector, adopts the most advanced large scale integrated
circuit technology, the international standard of intelligent
technology level design technology and proprietary digital
simulation mixed communication technology and design completely
intelligent gas detection instrument. HSTDX50 series gas
detection instrument advanced technology, excellent performance,
high stability, can detect the gas variety, with recovery
factory default Settings and since diagnosis function, use and
maintenance convenience, greatly satisfy the industrial site
safety monitoring of equipment with high reliability
requirements, widely used in petroleum, chemical, environmental
protection, metallurgy, refining, gas transmission and
distribution, biological medicine, agriculture, etc
2. Technical characteristics
* High precision, high resolution.
* Broad range, the most massive ranges from 0 to 50000ppm or
0~100% Vol.
* Plug and play international standard intelligent sensor,
on-site maintenance is very convenient.
* Unique LCD with backlighting design technology, field
observation, the maintenance of equipment beset by changing
light no longer Entire range range of digital temperature
compensation.
* Through three buttons can realize
view, setting, calibration, and other functions.
* This Ann circuit design, shell rainproof, corrosion resistance
and wear resistance.
* Large capacity rechargeable lithium battery and charging
protection circuit.
* A key to restore function, let you when operating worry-free.
3.Technical parameters
Shell material: ABS
Envelop dimensions: 125¡Á52¡Á30mm(L¡ÁW¡ÁH)
Explosion-proof level: Exia II CT6
Protective level: IP65
The weight: 200g
Accuracy: ¡À3%F.S.
Detecting way: Diffusion Type or Pump suction method
Concentration unit: ppm, %VOL, %LEL, mg/m3
Acousto-optic alarm means:, vibration
Working temperature: - 40 ~ 70ºC
Work humidity: 0 ~ 95% RH not gel
Working voltage: 3.6 VDC
Alarm current: 120mA
The working current: Diffusion Type 10mA, pump suction method 60mA
Battery capacity: 1800mA, take charge protection circuit
Charger specification: 4.2 VDC, 1A
|
¡¡ |
¡¡ |
|
HSTDX207
2 in 1 FORMALDEHYDE (CH2O),
Humidity DETECTOR
Technical Specifications
1. Range
a. Humidity: 30-90%RH
b. Formaldehyde:
0-4.00 PPM or 0-5.00mg/m3
2. Resolution:
a. Humidity: 1%RH
b. Formaldehyde:
0.01PPM,0.01mg/m3
3. Response time: 30s at 20¡ãC
4. Sampling Method: Diffusion type
5. Display: Four digits LCD
Operation Instructions:
1.Turn on the meter, around 30
seconds for warm-up.
2.After waiting 30 seconds, the
screen displays "----" for humidity collection.
3.After around 5 seconds, the ambient
temperature test is completed, the measurement result shows 76%
RH.
4.When testing formaldehyde ,put the
meter outside room, click "CH2O" button, then wait 30 seconds
collection, the screen displays "----".
5.After 30 seconds collection, the
meter setting the base point 0,the screen displays "0.00"
6.Put the meters to the environment
for testing (inside cars, outdoors), press "SCAN" button to
test, wait 30 seconds, the screen displays "----".
7.Wait after 30 seconds, the test is
completed, now the screen displays showing the formaldehyde
content (the proportion of formaldehyde in the air is very
small, longer time need for collecting.
If changes another environment, Next
time, just click the "SCAN" button, the instrument will display
the measured concentration of formaldehyde in the new
environment.
Note: If the procedure returns to the
step of humidity measurement or shut down, you still need to set
the base point 0 before testing, and then measured. |
|
|
|
SRVOC-1 Portable VOC Gas Detector
Summary:
SRVOC-1 VOC is the world's smallest portable gas detector, using
a new generation of imported PID VOC sensor, safe and reliable,
can provide security for staff who under the poisonous gases in
hazardous environments.
Features:
* Small size, light weight, easy to carry;
* High accuracy, short response time, wide measurement range;
* Large-screen color LCD graphic display, more comfortable and
humane;
* English menu display;
* USB rechargeable lithium battery, long life, fast and easy
charging;
* Built-in large capacity memory, can store large amounts of
measurement data;
* Powerful sound and light alarm, vibration alarm variety of
alarm mode;
* Water and dust-proof, explosion proof, rugged enclosure drop
resistance protection, high degree of protection;
* Support USB and the upper machine communications, the upper
machine Calibration;
* Warning lights flashing, convenient to work in the dark;
* PPM and mg/m3 switch, conveniet user to reading.
Parameters:
Product type: Diffused VOC gas detector with data storage
Measurement Type: Volatile organic compounds (VOC)
Test range: 0~20/ 200/ 2000ppm
(Please indicated
the test range when you place an order)
Resolution: 0.01/ 0.1/ 1ppm
Accuracy: ¡À3%
Battery: Built-in rechargeable lithium battery
Operate time: Full power longer than 8 hours
Charging time: Less than 4 hours
Display: TFT color screen
Alarm method: Sound alarm, the red LED lights alarm, vibration
alarm
Keyboard: 4 keys
Sampling way: Diffusion
Date record: 30 seconds interval can be stored more than four
months of record
Calibrate: 2 Point calibration, calibration values can be set
Operating temperature: -20~55¡ãC
Operating humidity: 0-95% relative humidity (non-condensing)
Dimension: 110*68*38mm
Weight: 200g
Warranty: 1 year |
¡¡ |
¡¡ |
¡¡
¡¡
Application to below gas types:
1) Aromatic Hydrocarbon: Benzene, Toluene, Xylene, Isopropyl
benzene, etc.
2) Unsaturated Hydrocarbon: Ethyne, Ethylene, Butadiene, etc.
3) Chlorinated Hydrocarbon: Vinyl chloride, Chloroform,
Trichloroethylene, Methylene dichloride, etc.
4) Ketone:
Acetone, Ethyl methyl ketone, Isobutyl ketone, etc.
5) Alcohols: Methyl alcohol, Ethanol, Isopropranol, Butanol,
etc.
6) Aldehydes:
Formaldehyde, Acetaldehyde, etc.
7) Organic fuel: gasoline, aircraft fuel, etc. |
SRVOC-2
Portable VOC Detector
Summary:
Used advanced PID (photoionization detector) sensor which can
response rapid and exactly. Specializes in measurement of indoor
air quality VOCs (volatile organic compounds), such as benzene,
methyl benzene, xylene, alcohols, ethers, esters, etc.
It
is primary inspection tool to inspect the toxic gas
concentration in industrial environment continuously, especially
applicable to personal safety protection and VOC spot
inspection.
Features:
1. Small in size
and light in weight; Shake-proof, explosion-proof and
flame-retardant housing/shell
2. Continuously LCD real-time display of gas concentration and
composition
3. Rechargeable lithium battery
4. 95 dB acoustic alarm and two wide-angle optic alarm
5. Built-in vibration alarm which is applied for noisy
environment
6. Two stage alarm threshold: the low and high alarm points can
be adjusted according to actual needs
7. Simple automatic calibration program and plug-in replaceable
electrochemical sensor
8. Fully functional self-testing: sensor, integrity of battery
and circuit, acoustic & visual & vibration three-stage alarm
Technical Specifications:
Applicable Gas: Volatile organic compounds VOC
Sensor Type: PID (photoionization detector) sensor
Detecting Range: 0~200ppm & 0~2000ppm
Resolution: 1ppm
Sampling Method: Diffusion or pump suction (optional)
Display: LCD display with backlight
Accuracy: ¡Ü¡À3%£¨F.S£©
Alarm Type: Audible-visual-vibration alarm Battery under-voltage
alarm
Response Time: t<30s
Restoring Time: <30s
Sensor Life: 3 years
Power Supply: DC 3.6V rechargeable battery, 1800mA
Operating Environment: Temperature: -20¡ãC~70¡ãC
Humidity: ¡Ü95%RH (non-condensing)
Explosion-proof Type: Intrinsically safe |
¡¡ |
¡¡ |
¡¡
¡¡
¡¡
Functions:
Monitor gas concentration in an environment or an enclosed space
Self-calibration and zero calibration functions, which make the
measurement more precise
One press to restore factory setting, free from the bother of
mis-operation
With temperature and pressure compensation, be able to realize
gas concentration compensation under conditions of different
temperatures or pressures
Alarm with sound and light on site, two alarm point values are
settable
Rechargeable lithium polymer batteries of large capacity
Pumping sampling method, adjustable pumping suction
Special engineering plastics housing of high intensity,
anti-skipping, waterproof, dust-proof, explosion-proof
Elegant and exquisite aluminum alloy suitcase
Applications:
Petroleum chemical industry, industrial production, smelting and
forging, electric power, coal mining, tunnel engineering,
environmental monitoring and sewage disposal.
Biological pharmaceutical, household environmental protection,
animal husbandry and livestock breeding, greenhouse cultivation,
warehousing and logistics, brewing and fermentation,
agricultural production.
Fire prevention, gas, building construction, municipal
enterprises, scientific research center, and school laboratory |
SRVOC-11 & SRVOC-12 & SRVOC-13
Pumping VOC Detector
Summary:
A
portable gas detector with built-in micro sampling pump of
high-precision; Optional data storage function, which be able to
store up to a hundred thousand sets of data, USB data interface
can be connected to the computer, available for data downloading
and printing: There are various and switchable units of gas
concentration such as PPM, mg/m3 and so on; LCD dot matrix
display technology, support graphic.
Features:
* Imported high-precision sensor with original packaging
* High-speed data transmission by USB, available for data
downloading and printing (optional)
* Data storage function, which be able to store up to a hundred
thousand sets of data, adjustable storage interval time
* LCD dot matrix display technology, be able to display type of
gas, gas unit, gas concentration, maximum measurement value
(optional), local time, the
environment temperature (optional)
* Support Chinese and English operation interface, easy to shift
* Easy to switch between gas concentration unit of PPM and mg/m3
* Built-in micro sampling pump, there are ten grades of pumping
suction for your selection
* Explosion-proof Conformity Certification, Explosion-proof
Grade: Exia II CT4
Specifications
Target Gas |
VOC |
Principle of Detection |
Electrochemical for SRVOC-11;
PID for SRVOC-12 & SRVOC-13 |
Sampling Method |
Pumping, with flow up to 1L/min, ten grades of pumping
suction for selection |
Range of Measurement |
SRVOC-11: 0-10PPM,
0-50PPM, 0-100PPM
(selectable) |
SRVOC-12: 0-10PPM, 0-50PPM, 0-100PPM
(selectable) |
SRVOC-13: 0-1PPM |
Resolution |
SRVOC-11:
0.01ppm;
SRVOC-12:
0.01ppm;
SRVOC-13: 0.001ppm |
Precision |
SRVOC-11:
3%FS;
SRVOC-12: 2%FS; SRVOC-13: 2%FS |
Data Storage |
Up to a hundred thousand sets of data, high-speed data
transmission by USB, available for data downloading and
printing (optional) |
Time of Responsible |
¡Ü10S |
Time of Recovery |
¡Ü10s |
Repeatability |
¡Ü¡À1% |
Linear Error |
¡Ü¡À1% |
Zero Drift |
¡Ü¡À1 (F.S/Year) |
Display Technology |
LCD dot matrix display technology |
Operation Language |
Support Chinese and English |
Unit of gas |
Switchable among several units |
Temperature Limit |
-40¡ãC~70¡ãC |
Humidity Limit |
0-95%RH |
Explosion-Proof Grade |
Exia
II
CT4 |
Protection Grade |
IP66 |
Alarm Mode |
Sound, light and vibration |
Time of Operation |
100hours (pump off) |
Dimensions |
205*75*32mm |
Weight |
300g |
|
¡¡ |
¡¡ |
¡¡
¡¡
Applications:
Petroleum, petrochemical, chemical,
environmental, paper, paints, coatings, mining, electroplating,
textile, coking plants, indoor air quality monitoring,
environmental monitoring systems, health monitoring systems.
Standard Configuration:
Gas Detection Instrument 1Set
Lithium Battery 1Piece
Battery charger and USB line 1Set
Package box 1Set
Lithium battery 1Set
Operational Manual 1Piece
Product inspection report 1Piece
Products packing 1Set
Metal ventilation pipe [straight pipe / Curved pipe ] 1Set |
SRVOC-14 Pump-priming Portable TVOC
Gas Detector
Summary:
SRVOC-14 Pump-priming Portable TVOC
Gas Detector is a continuous monitoring of TVOC gas single gas
detection equipment. This product is suitable for environmental
monitoring, industrial production and other harmful gases
working environment, which
can effectively protect the health and safety of staff is not
compromised.
Features:
* Intelligent Probe design;
convenient calibration and maintenance;
* Fault, Warning, operator error, alarm will be smart tips;
* Built-in CF calibration coefficients (VOC measurements only
valid);
* With audible alarm, visual alarm function, the status bar also
displays alarm status;
* Full-color 3.5-inch TFT screen, color LCD display and
intuitive;
* Can be both digital and curve display of gas concentration in
two ways;
* With USB communication port, you can speed 9600 bytes to
communicate directly with the computer;
* With test record function, can store a month's measurement
data and instrument or computer can view the data; Memory
capacity is 2M,can store more than 90,000 pieces of data.
* With alarm recording function, you can record the last four
times the alarm time and type;
* With calibration record; can record the last four times the
size of the calibration time span;
* High-capacity lithium battery-powered, rechargeable, low
battery automatic shutdown;
* Can be set high reported, underreporting, TWA, STEL, shutdown
time, pump speed etc;
* Indicate way: LCD display
real-time concentration, LED, buzzer alarm.
Parameters:
Sensor type: Photoelectric Ion
Sampling way: Pump type
Test range: 0-2/ 20/ 200/ 2000/ 10000ppm
(Please
indicated the test range when you place an order)
Resolution: 0.1/ 0.1/ 1ppm
Accuracy: ¡À5%FS
Response time: <20s
Indicate way: LCD display real-time concentration, LED, buzzer
alarm
Data storage: Can store multiple sets of data
Pressure range: Atmospheric pressure 10%
Power supply: Lithium battery (4.2V/3000mAh)
Operating Current: normal current:¡Ü 150mA; Alarm current: ¡Ü
200mA
Operating Temperature: -40¡ãC~70¡ãC
Relative Humidity :15% - 95%, non-condensing
Storage Temperature: -20¡ãC~60¡ãC
Storage humidity: ¡Ü 90%, no condensation
Sensor life: 1 year
Continuous work hours: 30 hours above
Charge time: 6-8 hours
Housing material: PC
Dimensions: 228* 84 * 50.5mm
Installation: Handheld / Stand-in
Weight: 0.55 kg
Protection Class: IP65
Certification: CE
Warranty: 12 months |
¡¡ |
¡¡ |
|
SRVOC-15 Portable VOC Detector with
Built-in Suction Pump
Summary:
Portable gas detector SRVOC-15 is an
intrinsically safe device to inspect single gas concentration in
ambient air continuously and rapidly. It has high accuracy and
fast response.
The sampling method of model SRVOC-15 is pump suction. Large LCD
matrix display screen and high brightness backlight provide a
clear indication for gas concentration, detection range, battery
status, alarm condition, current time, temperature and humidity
(optional).
Features:
1. Wide range
2. Rapid response
3. High accuracy
4. Function of setting for alarm and time
5. Large storage capacity
6. Non-preheat
7. High brightness backlight display
8. User operated calibration
9. Simple operating and safety working
10. Digital temperature and humidity sensor
(optional)
Technical Specifications:
Gas Types: Volatile organic compounds VOC
Detection Range: 0~200ppm & 0~2000ppm
Resolution: 1ppm
Sampling: Pump-suction
Working Principle: PID
Response Time: T<30s
Linearity: <1% of Full Scale
Unit of Concentration: %VOL / PPM / %LEL
Storage Capacity: 999 group of data
Working Environment: Temperature: -20¡ãC~50¡ãC Humidity: <95%RH
Power Supply: Lithium battery (1200mAh)
Dimension 80(W)*36(D)*150(H) mm
Weight: About 200g |