PROVA-11 AC/DC mA True RMS Clamp Meter

  • Super High Resolution DC 1mA, AC 0.1mA

  • One Touch Zero for DCA

  • True RMS

 

 

Range 

Output 

Accuracy 

DCA 0-4000mA

1mA

+/- 1.5%rdg +/- 5dgts

¡¡

DCA 0-30A

10mA

+/- 1.5%rdg +/- 3dgts

¡¡

ACA 0-400mA

0.1mA

+/- 1.5%rdg +/- 5dgts

True RMS

ACA 0-4000mA

1mA

+/- 1.5%rdg +/- 8dgts

True RMS

ACA 0-30A

10mA

+/- 2.0%rdg +/- 5dgts

True RMS

DCV 0-400V

0.1V

+/- 1.0%rdg +/- 3dgts

¡¡

ACV 0-400V

0.1V

+/- 2.0%rdg +/- 5dgts

True RMS

Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition: -10 ºC to 50 ºC at 85% max. RH

CM-01 DC/AC Clamp Meter

  • High Resolution DC/AC 10mA

  • 23 mm Large Jaw Diameter

  • One Touch Zero for DCA adjustment

 

 

Range 

Resolution 

Accuracy 

Remarks 

DCA 0-40A

10mA

+/- 1.0% +/- 2dgts

¡¡

DCA 0-150A

100mA

+/- 1.0% +/-2 dgts

¡¡

DCA 150-200A

100mA

-2.2% +/- 2dgts

¡¡

ACA 0-40A

10mA

+/- 1.0% +/- 3 dgts

¡¡

ACA 0-150A

100mA

+/- 1.0% +/- 3 dgts

¡¡

ACA 150-200A

100mA

-2.2% +/- 3dgts

¡¡

DCV 0-400V

0.1 V

+/- 1.0% +/- 2dgts

¡¡

ACV 0-400V

0.1 V

+/- 1.0% +/- 2 dgts

¡¡

W 0-400 W

0.1 W

+/- 1.0% +/-2dgts

beep if < 40 W (Approx.)

Hz 0-1000KHz

0.1-100

+/- 0.5% +/- 2dgts

1V sensitivity Auto Range

Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition: -10 ºC to 50 ºC at 85% max. RH

PROVA-5601 Clamp-on Ground Resistance Tester

  • Non-Contact Ground Resistance Measurement

  • No Auxiliary Electrode Needed

  • Jaw Diameter ¦µ 23 mm (5601)

  • 0.025 ¨C 1500 Ohm

  • 0.2mA¨C 30A(5601),True RMS

  • 116 Sets of Memory

  • Programmable Hi and Lo Alarm

  • Programmable Data Logging

  • Telecommunication

  • Cable TV system

  • Electrical Power Plant

  • Cellular Phone System

  • Factory and Facility

  • Gas Station Tank

¡¡

Ground Resistance (Auto range)

Range 

Resolution 

Accuracy of Reading 1, 2 

0.025 - 0.250 ¦¸

0.002 ¦¸

¡À 1.5% ¡À 0.05 ¦¸

0.250 - 1.000 ¦¸

0.02 ¦¸

¡À 1.5% ¡À 0.05 ¦¸

1.001 - 9.999 ¦¸

0.02 ¦¸

¡À 1.5% ¡À 0.1 ¦¸

10.00 - 50.00 ¦¸

0.04 ¦¸

¡À 2.0% ¡À 0.3 ¦¸

50.01 - 99.99 ¦¸

0.04 ¦¸

¡À 2.0% ¡À 0.5 ¦¸

100.0 - 200.0 ¦¸

0.4 ¦¸

¡À 3.0% ¡À 1.0 ¦¸

200.1 - 400.0 ¦¸

2 ¦¸

¡À 5.0% ¡À 5 ¦¸

400.1 - 600.0 ¦¸

5 ¦¸

¡À 10% ¡À 10 ¦¸

600.1 - 1500 ¦¸

20 ¦¸

¡À 20%

1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered.

2 Resistance Measurement Frequency: 1.667KHz, 3.333KHz(optional)

Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5)

Range 

Resolution 

Accuracy of Reading 

0.200 - 1.000 mA

0.001 mA

¡À 2.0% ¡À 0.05 mA

1.00 - 10.00 mA

0.01 mA

¡À 2.0% ¡À 0.03 mA

10.0 - 100.0 mA

0.1 mA

¡À 2.0% ¡À 0.3 mA

100 - 1000 mA

1 mA

¡À 2.0% ¡À 3 mA

0.20 - 4.00 A

0.001A

¡À 2.0% ¡À 0.03A

4.00 - 30.00 A(5601)

0.01A

¡À 3.0% ¡À 0.03A

General Specification

Accuracy of Resistance Calibration Plate

¡À0.5% 

Data Logging Capacity

116 records 

Data Logging Interval

1 to 255 seconds 

Conductor Size

23mm /0.90"(5600,5601) 

Jaw Opening

27mm /1.06"(5600,5601) 

Battery Type

9V IEC 6 LR61 (Alkaline) 

Display Type

4 digits 9999 counts LCD 

Overload Indication

OL 

Battery Life

3000 measurements 

Range Selection

Auto 

Power Consumption

40mA 

Sampling Time

0.5 seconds 

Operating Temperature

0ºC to 50ºC (14ºF to 122ºF ) Operating Humidity: Less than 85% RH 

Storage Temperature

-20ºC to 60ºC (-4ºF to 122ºF ) Storage Humidity: Less than 75% RH 

Dimension( 5600, 5601 )

257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H) 

Weight( 5600, 5601)

640g/1.41lbs 

Accessories

Resistance Calibration Plate x 1 

Battery 9V (Installed) x 1 

Carrying Box x 1 

Users Manual x 1 

CM-02/04 Clamp Meter/Automotive Clamp

  • DC/AC 0.01A Resolution

  • AC/DC 0.01A~200A

  • 23mm Jaw Diameter

  • One Touch Zero

  • Temperature and Capacitance

  • Auto Range V. W .Hz. o C.

  • 3 3/4 Digits (4000 Counts)

  • 0~9999 RPM(CM-04)

 

DC Current

Range

Resolution

Accuracy

Overload Protection

40A

10mA

+/-1.5%+/-2dgts

DC400A

0-150A

0.1A

+/-1.5%+/-2dgts

DC400A

150-200A

0.1A

+/-1.5.5%+/-3dgts

DC400A

RPM (CM-04 with adaptor)

Range

Resolution

Accuracy

Remarks

0~9999

1RPM

+/-0.5%+/-2dgts

¡¡

AC Voltage (Autorange, Input Impedance 5M W )

Range

Resolution

Accuracy

Overload Protection

4V

0.001V

+/-1.5%+/-5dgts

800VAC

40V

0.01V

+/-1.5%+/-5dgts

800VAC

400V

0.1V

+/-1.5%+/-5dgts

800VAC

600V

1V

+/-1.5%+/-5dgts

800VAC

DC Voltage (Auto range, Overload Protection 800VAC )

Range

Resolution

Accuracy

Input Impedance

400 mV

0.1 mV

+/-1.5%+/-3dgts

10M W

4V

0.001V

+/-1.5%+/-3dgts

5M W

40V

0.01V

+/-1.5%+/-3dgts

5M W

400V

0.1V

+/-1.5%+/-3dgts

5M W

600V

1V

+/-1.5%+/-3dgts

5M W

Frequency (Hz, Autorange & Sensitivity selected by range button)

Range

Resolution

Accuracy

Sensitivity

Overload Protection

100-1000kHz

0.01-100Hz

+/-0.5%+/-2dgts

10 mV /0.1V/1V

AC600V

Resistance( W )&Audible Continuity (Open Circuit Voltage 0.5V):

Range

Resolution

Accuracy

Beeper

Overload Protection

40-400 W

0.1 W

+/-1.0%+/-5dgts

<=40 W (approx)

AC600V

AC Current

Range

Resolution

Accuracy

Overload Protection

¡¡

¡¡

50/60Hz

40-400Hz

¡¡

40A

10mA

+/-1.5%+/-3dgts

+/-2.5%+/-3dgts

AC400A

0-150A

0.1A

+/-1.5%+/-3dgts

+/-2.5%+/-3dgts

AC400A

150-200A

0.1A

+/-2.0%+/-3dgts

+/-3.0%+/-3dgts

AC400A

Resistance( W )(Autorange & Manual, Open Voltage<=0.5V)

Range

Resolution

Accuracy

Overload Protection

400 W

0.1 W

+/-1.5%+/-3dgts

600VAC

4K W

1 W

+/-1.5%+/-3dgts

600VAC

40K W

10 W

+/-1.5%+/-3dgts

600VAC

400K W

100 W

+/-1.5%+/-3dgts

600VAC

4M W

1K W

+/-1.5%+/-3dgts

600VAC

40M W

10K W

+/-1.5%+/-3dgts

600VAC

Capacitance (Autorange & Manual)

Range

Resolution

Accuracy

Overload Protection

4nF

1pF

+/-5.0%+/-0.2 nF

AC600V

40nF

10pF

+/-5.0%+/-0.2 nF

AC600V

400nF

0.1nF

+/-3.0%+/-0.2 nF

AC600V

4uF

1nF

+/-3.0%+/-0.2 uF

AC600V

40uF

10nF

+/-3.0%+/-0.2 uF

AC600V

TEMP K TYPE ºC (Autorange & Manual, ºF optional):

Range

Resolution

Accuracy

Overload Protection

-40 - 0 ºC

0.1 ºC

+/-2.0 %+/-5 ºC

AC600V

0- 400 ºC

0.1 ºC

+/-0.5 %+/-1 ºC

AC600V

400- 1200 ºC

1 ºC

+/-0.8 %+/-1 ºC

600V

General Specification

Conductor Size

23mm Diameter

Battery

1.5V AA UM3 Battery x 2

Display

3 3/4Diguts (4000Counts)

Range Selection

Auto and Manual

Power Consumption

10mA (Approx)

Sampling Time

2Time/sec (Digital) 20Time/sec (Bar graph)

Operating Temperature

0 ºC ~ 50 ºC (32 ºF ~122 ºF)

Operating Humidity

LESS than 80% RH

Dimension

7.2"(L) x 2.5"(W) x 1.4"(H)
183mm(L) x 63.6mm(W) x 35.6mm(H)

Weight

190g. (Batteries Included)

Accessories

Adaptor (for K-type Thermocouple and Capacitor) x 1
User Manual x 1
5V Battery x 2
K-type Thermocouple x 1
Carrying Bag x 1

Option

RPM Adaptor(COM04) x 1

CM-03 Leakage Current Tester
  • 10 m A Ultra High Resolution
  • Large Conductor Diameter (30mm)
  • ACA 5 Ranges (40mA, 400mA, 4A, 40A, 60A)
  • It can measure up to 400A, but over 60A, the measuring result has not been calibrated.
 
Range
Resolution
Accuracy

50/60Hz

Wide
ACA 0-40mA
10 uA
+/- 1.0% rdg +/- 3 dgts
+/- 2.0% rdg +/- 5 dgts (40 to 1KHz)
ACA 0 -400mA
100 uA
+/- 1.0% rdg +/- 3 dgts
+/- 2.0% rdg +/- 5 dgts (40 to 1KHz)
ACA 0-4A
1mA
+/- 1.0% rdg +/- 3 dgts
+/- 2.0% rdg +/- 5 dgts (40 to 1KHz)
ACA 0-40A
10mA
+/- 1.0% rdg +/- 3 dgts
+/- 2.0% rdg +/- 5 dgts (40 to 1KHz)
ACA 0-60A(0-50A)
0.1A
+/- 1.5% rdg +/- 3 dgts
+/- 3.0% rdg +/- 5 dgts (40 to 1KHz)
ACA 0-60A(50-60A)
0.1A
+/- 3.0% rdg +/- 5 dgts
+/- 3.5% rdg +/- 5 dgts (40 to 1KHz)
ACV 0-400V
0.1V
+/- 1.5% rdg +/- 2 dgts
+/- 2.0% rdg +/- 4 dgts (40 to 1KHz)
W 0-400 Ohm
0.1 Ohm
+/- 1.0% rdg +/- 2 dgts
Beef if < 40 W
Power Source:
2 X 1.5V SUM-3 Batteries
¡¡
Operation Temperature/Humidity:
-10 ºC  to 50 ºC  at 85% max.
CM-05 DC/AC Current Probe
  • Accurate and High Resolution
  • 23 mm Conductor Diameter
  • One Touch Zero
 

Range

Output

Sensitivity

Accuracy

DCA 0-4A
DC 100mV/A
10mA/mVDC
+/- 2.0% +/- 0.005A
DCA 0-40A
DC 10mV/A
0.1A/mVDC
+/- 1.0% +/- 0.02A
DCA 0-150A
DC 1mV/A
1A/mVDC
+/- 1.0% +/- 0.2A
DCA 150-200A
DC 1mV/A
1A/mVDC
-2.2% +/- 0.2A
ACA 0-4A
AC 100mV/A
10mA/mVAC
+/- 2.0% +/- 0.003A
ACA 0-40A
AC 10mV/A
0.1A/mVAC
+/- 1.5% +/- 0.03A
ACA 0-150A
AC 1mV/A
1A/mVAC
+/- 1.5% +/- 0.3A
ACA 150-200A
AC 1mV/A
1A/mVAC
-2.2% +/- 0.3A

Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption: 8mA
Operating Condition: -10 ºC  to 50 ºC  at 85% max. RH

CM-07 TRMS DC/AC Clamp Meter
  • High Resolution DC 10mA, AC 1mA
  • True RMS
  • Non-contact Current Frequency Measurement

 

 

Range

Resolution

Accuracy

Remarks

DCA 0-40A
10mA
+/- 1.0% +/- 2dgts
¡¡
DCA 0-150A
100mA
+/- 1.0% +/- 2dgts
¡¡
DCA 150-200A
100mA
- 2.2% +/- 2dgts
¡¡
DCA 200-400A
100mA
- 4.0% +/- 4dgts
¡¡
ACA 0-4A
1mA
+/- 1.5% +/- 3dgts
True RMS
ACA 0-40A
10mA
+/- 1.0% +/- 3dgts
True RMS
ACA 0-150A
100mA
+/- 1.0% +/- 3dgts
True RMS
ACA 150-200A
100mA
- 2.2% +/- 3dgts
True RMS
ACA 200-400A
100mA
- 4.0% +/- 4dgts
True RMS
Hz 0-1000KHz
0.1-100Hz
+/- 0.5% +/- 2dgts
0.1A sensitivity Auto Range

Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition: -10 ºC  to 50 ºC  at 85% max. RH

PROVA-15 AC/DC mA Current Probe
  • High Resolution DC 1mA, AC 0.1mA
  • Connect to an Oscilloscopes to observe Current Waveform
  • Connect to Chart Recorder/Datalogger/ DMM to Record Current Data

 

 

Range

Output

Sensitivity

Accuracy

DCA 0-400mA
DC 1mV/A
1mA/mV DC
+/- 2.0% +/- 1mV
DCA 0-4A
DC 100mV/A
10mA/mV DC
+/- 1.0% +/- 0.5mV
DCA 0-30A
DC 10mV/A
0.1A/mV DC
+/- 1.0% +/- 0.3mV
ACA 0-400mA
AC 1mV/A
1mA/mV AC
+/- 2.0% +/- 0.5mV
ACA 0-4A
AC 100mV/A
10mA/mV AC
+/- 1.5% +/- 0.8mV
ACA 0-30A
AC 10mV/A
0.1A/mV AC
+/- 1.5% +/- 0.3mV

Power Source: 2 X 1.5V AA UM3 Batteries

Current Consumption: 10mA

Operating Condition: -10 ºC  to 50 ºC  at 85% max. RH

( If you need user manual or E-catalogue for above meters, please ask for at: xiushunjie@gmail.com )